A preliminary study evaluating cardiac output measurement using Pressure Recording Analytical Method (PRAM) in anaesthetized dogs

نویسندگان

  • Angela Briganti
  • Flavia Evangelista
  • Paola Centonze
  • Annaliso Rizzo
  • Francesco Bentivegna
  • Antonio Crovace
  • Francesco Staffieri
چکیده

BACKGROUND Haemodynamic variations normally occur in anaesthetized animals, in relation to the animal status, administered drugs, sympathetic and parasympathetic tone, fluid therapy and surgical stimulus. The possibility to measure some cardiovascular parameters, such as cardiac output (CO), during anaesthesia would be beneficial for both the anaesthesia management and its outcome. New techniques for the monitoring of CO are aimed at finding methods which are non invasive, accurate and with good trending ability, which can be used in a clinical setting. The aim of this study was to compare the Pressure Recording Analytical Method (PRAM) with the pulmonary artery thermodilution (TD) for the measurement of cardiac output in 6 anaesthetized critically ill dogs. RESULTS Fifty-four pairs of CO measurements were obtained with a median (range) of 3.33 L/min (0.81-7.21) for PRAM-CO and 3.48 L/min (1.41-6.56) for TD-CO. The Bland-Altman analysis showed a mean bias of 0.17 L/min with limits of agreement (LoA) of - 0.46 to 0.81 L/min. The percentage error resulted 18.2%. The 4-quadrant plot analysis showed an acceptable concordance (93%) between the 2 methods. The polar plot showed a good trending ability with the mean angular bias of 3.9° and radial LoA ± 12.1°. CONCLUSIONS The PRAM resulted in good precision, acceptable concordance and good trending ability for the measure of CO in the anaesthetized dog, representing a promising alternative to thermodilution for the measurement of CO. Among all the pulse contour methods available on the market it is the only one that does not require any calibration or adjustment of the measurement. Further studies are required to verify the ability of this method to accurately measure cardiac output even during unstable hemodynamic conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between pressure-recording analytical method (PRAM) and femoral arterial thermodilution method (FATD) cardiac output monitoring in an infant animal model of cardiac arrest

BACKGROUND The pressure-recording analytical method is a new semi-invasive method for cardiac output measurement (PRAM). There are no studies comparing this technique with femoral artery thermodilution (FATD) in an infant animal model. METHODS A prospective study was performed using 25 immature Maryland pigs weighing 9.5 kg. Fifty-eight simultaneous measurements of cardiac index (CI) were mad...

متن کامل

Pressure recording analytical method (PRAM) for measurement of cardiac output during various haemodynamic states.

BACKGROUND Cardiac output (CO) can be measured using the pressure recording analytical method (PRAM), which is a new, less invasive technique allowing beat-by-beat stroke volume monitoring from the pressure signals recorded in femoral or radial arteries. METHODS We investigated PRAM by comparing its cardiac output (PRAM-CO) with paired measurements obtained by electromagnetic flowmetry (EM-CO...

متن کامل

Cardiac output monitoring by pressure recording analytical method in cardiac surgery.

OBJECTIVE A less-invasive method has been developed that may provide an alternative to monitor cardiac output from arterial pressure: beat-to-beat values of cardiac output can be obtained by pressure recording analytical method (PRAM). The purpose of this study was to assess the reliability of cardiac output determination by PRAM in cardiac surgery. METHODS Cardiac output was measured in 28 p...

متن کامل

Pressure recording analytical method for measuring cardiac output in critically ill children: a validation study.

BACKGROUND Pressure recording analytical method (PRAM) is a novel, arterial pulse contour-based method for measuring cardiac output (CO). Validation studies of PRAM in children are few, and have not assessed both absolute accuracy and ability to track changes in CO across a broad case mix. We aimed to compare CO as measured by PRAM with that using a transpulmonary dilution method in a cohort of...

متن کامل

Most Care®: a minimally invasive system for hemodynamic monitoring powered by the Pressure Recording Analytical Method (PRAM)

Invasive hemodynamic monitoring is a cornerstone of the care of critically ill and hemodynamically unstable patients in both intensive care units and operating rooms. The assessment of cardiac output by means of the pulmonary artery catheter has been considered the clinical gold standard. Nevertheless, several concerns have been raised regarding its invasiveness, usefulness, and associated comp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2018