Study on the Characteristic Decomposition Components of DC SF6-Insulated Equipment under Positive DC Partial Discharge

نویسندگان

  • Min Liu
  • Xin Liu
  • Qiang Yao
  • Yulong Miao
چکیده

Pulses with different amplitudes occur when an inner partial discharge fault exists in SF6-gas-insulated DC high-voltage electrical equipment. SF6 decomposes following complex physical and chemical processes. Discussing and quantifying the mathematical relationship of pulse discharge quantities to SF6 decomposition component characteristics is helpful to evaluate and predict the insulation fault severity and development trends in SF6-insulated DC equipment. Numerous simulation experiments on SF6 decomposition under positive DC partial discharge were performed on a needle-plane model. The DC partial discharge quantities of pulses are obtained, and decomposition characteristics based on the mechanism of SF6 decomposition are analyzed. Results show that generation, effective generation rate and concentration ratio c(SO2F2 + SOF4)/c(SOF2 + SO2) of components increase with partial discharge severity, and the first two act in the following order: SOF4 > SOF2 > SO2F2 > SO2 > CF4 when the discharge quantity level is higher than 238,957 pC. Finally, a coefficient matrix illustrates the mathematical effects of pulses with different discharge quantities on different SF6 decomposition components. The pulses whose discharge quantity is higher than 50 pC have obvious promotion effects on the formation of decomposition components, whereas the pulses whose discharge quantity lower than 50 pC decrease the positive promotion effects that large discharge pulses have on decomposition components. The higher the effective generation rates are, the greater the partial discharge severity is, and their change laws provide a new method to evaluate and predict insulation fault severity and development trends in DC SF6-insulated equipment with high reliability and detection stability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Decomposition Characteristics of SF6 and Partial Discharge Recognition under Negative DC Conditions

Four typical types of artificial defects are designed in conducting the decomposition experiments of SF6 gas to obtain and understand the decomposition characteristics of SF6 gas-insulated medium under different types of negative DC partial discharge (DC-PD), and use the obtained decomposition characteristics of SF6 in diagnosing the type and severity of insulation fault in DC SF6 gas-insulated...

متن کامل

Correlation Characteristics Comparison of SF6 Decomposition versus Gas Pressure under Negative DC Partial Discharge Initiated by Two Typical Defects

Aimed to clarify the correlation characteristics between the internal partial discharge (PD) in negative direct current (DC) gas insulated system (GIS) and gas pressure initiated by two typical defects (i.e., free-metal particles and metal protrusion), this study on PD decomposition of sulfur hexafluoride (SF6) was investigated under different pressures on the basis of constructing a SF6 decomp...

متن کامل

Using SF6 Decomposed Component Analysis for the Diagnosis of Partial Discharge Severity Initiated by Free Metal Particle Defect

The decomposition characteristics of a SF6 gas-insulated medium were used to diagnose the partial discharge (PD) severity in DC gas-insulated equipment (DC-GIE). First, the PD characteristics of the whole process were studied from the initial PD to the breakdown initiated by a free metal particle defect. The average discharge magnitude in a second was used to characterize the PD severity and th...

متن کامل

A Pt-Doped TiO2 Nanotube Arrays Sensor for Detecting SF6 Decomposition Products

The detection of partial discharge and analysis of SF6 gas components in gas-insulated switchgear (GIS) is important for the diagnosis and operating state assessment of power equipment. The use of a Pt-doped TiO2 nanotube arrays sensor for detecting sulfur hexafluoride (SF6) decomposition products is proposed in this paper. The electrochemical pulse deposition method is employed to prepare the ...

متن کامل

Comparative Study of Materials to SF6 Decomposition Components

In order to judge the inside insulation fault of SF6 insulated equipment, the gas-sensing properties to a series of characteristic SF6 decomposition components, SOF2, SO2F2, SO2, H2S, CF4, HF, and SF6, have been studied. In this study, a comparative study of these gassensing materials has been made in theoretical and experimental fields to find the optimal gas-sensing material, and put forward ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017