Intermediate-term results after the aortic valve replacement using bileaflet mechanical prosthetic valve in children.
نویسندگان
چکیده
OBJECTIVE Intermediate/long-term results after aortic valve replacement using bileaflet mechanical valve in children should be clarified as a standard of treatment of aortic valve disease in children. METHODS Forty-five patients aged under 15 years underwent 46 aortic valve replacements using bileaflet mechanical prosthetic valve. Patients' ages ranged from 1 to 15 years (9 years as a median value), and follow-up period was 9.2 years as a median value (maximum 19 years). RESULTS In situ valve replacement was performed in 21 procedures, while annular enlargement was required in 25 procedures (Nicks 10, Yamaguchi 3, Manouguian 2, Konno 10). All patients except two received prosthesis 19mm or larger in size. There was one operative death and two late deaths. Two episodes of cerebral infarction, two valve thrombosis, two re-operations, one infective endocarditis, and one sudden death were recognized as valve-related complications in five patients. The reasons for re-operation were prosthesis-patient mismatch in one (Ross procedure) and valve thrombosis in one (re-replacement). At 15 years after the operation, re-replacement free rate, valve-related event free rate and actuarial survival rate were 94+/-4%, 86+/-6% and 92+/-4%, respectively. The transprosthetic flow velocity estimated by Doppler echocardiography at the final follow-up was well correlated with manufactured valve area index (cm(2)/body surface area). CONCLUSIONS Although aortic annular enlargement was required in more than half of the cases, intermediate-term results after aortic valve replacement using bileaflet mechanical prosthetic valve in children was satisfactory. Indications for alternative treatment such as Ross procedure might be considered in limited cases.
منابع مشابه
Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis
Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...
متن کاملمقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی
In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...
متن کاملMechanical Hemolysis after Mitral Valve Repair: Report of a Case
A 60-year-old man underwent aortic valve replacement with a bileaflet mechanical valve for aortic regurgitation and mitral valve repair using a prosthetic ring for mitral regurgitation (MR). Intraoperative transesophageal echocardiography (TEE) confirmed no residual MR and a normally functioning aortic prosthetic valve without a paravalvular leak. One week after the operation, transthoracic ech...
متن کاملMeasuring effective orifice area of bileaflet mechanical valves in patients after aortic valve replacement using phase-contrast cine MR imaging
Introduction Mismatch of patients and prostheses is a critical issue for patients undergoing aortic valve replacement (AVR), because it increases postoperative mortality. Mismatch can be determined by measuring the effective orifice area (EOA) of a prosthetic valve. Although EOA is usually measured by transthoracic ultrasonography, its accuracy remains unclear because the prosthetic valve and/o...
متن کاملFive-year follow-up after heart valve replacement with the CarboMedics bileaflet prosthesis.
BACKGROUND The CarboMedics valve is a relatively new, low-profile, bileaflet, mechanical prosthesis. The results of a prospective follow-up study after valve replacement with this prosthesis in a university hospital are presented. METHODS We implanted 640 CarboMedics prostheses in 583 patients in the aortic (n = 359), mitral (n = 167), or aortic and mitral positions (double valve replacement;...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 34 1 شماره
صفحات -
تاریخ انتشار 2008