Adrenergic, metabolic, and reflex abnormalities in reverse and extreme dipper hypertensives.
نویسندگان
چکیده
Limited information is available on whether and to what extent the different patterns of the nocturnal blood pressure profile reported in hypertension are characterized by differences in sympathetic drive that may relate to, and account for, the different day-night blood pressure changes. In 34 untreated middle-aged essential hypertensive dippers, 17 extreme dippers, 18 nondippers, and 10 reverse dippers, we assessed muscle sympathetic nerve traffic, heart rate, and beat-to-beat arterial blood pressure at rest and during baroreceptor deactivation and stimulation. Measurements were also performed in 17 age-matched dipper normotensives. All patients displayed reproducible blood pressure patterns at 2 different monitoring sessions. The 4 hypertensive groups did not differ by gender or 24-hour or daytime blood pressure. Muscle sympathetic nerve traffic was significantly higher in nondipper, dipper, and extreme dipper hypertensives than in normotensive controls (58.6+/-1.8, 55.6+/-0.9, and 53.3+/-0.8 versus 43.5+/-1.4 bursts/100 heartbeats, respectively; P<0.01 for all), a further significant increase being detected in reverse dippers (76.8+/-3.1 bursts/100 heartbeats; P<0.05). Compared with normotensives, baroreflex-heart rate control was similarly impaired in all the 4 hypertensive states, whereas baroreflex-sympathetic control was preserved. The day-night blood pressure difference correlated inversely with sympathetic nerve traffic (r=-0.76; P<0.0001) and homeostasis model assessment index (r=-0.32; P<0.005). Thus, the reverse dipping state is characterized by a sympathetic activation greater for magnitude than that seen in the other conditions displaying abnormalities in nighttime blood pressure pattern. The present data suggest that in hypertension, sympathetic activation represents a mechanism potentially responsible for the day-night blood pressure difference.
منابع مشابه
Stroke prognosis and abnormal nocturnal blood pressure falls in older hypertensives.
It remains uncertain whether abnormal dipping patterns of nocturnal blood pressure influence the prognosis for stroke. We studied stroke events in 575 older Japanese patients with sustained hypertension determined by ambulatory blood pressure monitoring (without medication). They were subclassified by their nocturnal systolic blood pressure fall (97 extreme-dippers, with >/=20% nocturnal systol...
متن کاملComparison of left atrial volume and function in non-dipper versus dipper hypertensives: A real-time three-dimensional echocardiography study
OBJECTIVE Non-dipper hypertension is associated with an increased cardiovascular morbidity and mortality. Besides this, the left atrial (LA) size and functions are accepted to be prognostic factors in various cardiovascular diseases. In this study, we aimed to evaluate the effect of nondipper hypertension on LA volume and functions using real-time three-dimensional echocardiography (RT3-DE). ...
متن کاملIncomplete benefit of antihypertensive therapy on stroke reduction in older hypertensives with abnormal nocturnal blood pressure dipping (extreme-dippers and reverse-dippers).
To determine whether the benefits of antihypertensive treatment vary according to dipper status, 811 asymptomatic elderly Japanese hypertensives underwent 24-h ambulatory blood pressure monitoring. During a mean follow-up period of 41 months, 32 stroke events were observed in patients who remained nonmedicated (n = 385), and in 27 patients in the medicated group (n = 426), indicating a 24% lowe...
متن کاملVariability of circadian blood pressure profile during 24-hour ambulatory blood pressure monitoring in hypertensive patients.
BACKGROUND Evaluation of circadian blood pressure (BP) profile is an important element of ambulatory BP monitoring (ABPM). Abnormal nocturnal fall in BP is more common in patients with secondary causes of hypertension and in the elderly. Cardiovascular risk is substantially increased in these patients. AIM Analysis of circadian BP profile in a population of treated hypertensives and identific...
متن کاملNon-dipper hypertension is associated with slow coronary flow among hypertensives with normal coronary angiogram
AIM A person with a drop of more than 10% in nocturnal arterial blood pressure during the circadian rhythm is referred to as a dipper and one with a smaller decrease is referred to as a non-dipper. In our study, we aimed to compare the thrombolysis in myocardial infarction (TIMI) frame count in non-dipper and dipper hypertensive patient groups who had normal coronary artery angiography. METHO...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Hypertension
دوره 52 5 شماره
صفحات -
تاریخ انتشار 2008