Computer-assisted algorithms improve reliability of King classification and Cobb angle measurement of scoliosis.
نویسندگان
چکیده
STUDY DESIGN Interobserver and intraobserver reliability study of improved method to evaluate radiographs of patients with scoliosis. OBJECTIVE To determine the reliability of a computer-assisted measurement protocol for evaluating Cobb angle and King et al classification. SUMMARY OF BACKGROUND DATA Evaluation of scoliosis radiographs is inherently unreliable because of technical and human judgmental errors. Objective, computer-assisted evaluation tools may improve reliability. METHODS Posteroanterior preoperative radiographic images of 27 patients with adolescent idiopathic scoliosis were each displayed on a computer screen. They were marked 3 times in random sequence by each of 5 evaluators (observers) who marked 70 standardized points on the vertebrae and sacrum in each radiograph. A computer program (Spine 2002;27:2801-5) that identified curves, calculated Cobb angles, and generated the King et al classification automatically analyzed coordinates of these points. The interobserver and intraobserver variability of the Cobb angle and King et al classification evaluations were quantified and compared with values obtained by unassisted observers. RESULTS Average Cobb angle intraobserver standard deviation was 2.0 degrees for both the thoracic and lumbar curves (range 0.1 to 8.3 degrees for different curves). Interobserver reliability was 2.5 degrees for thoracic curves and 2.6 degrees for lumbar curves. Among the 5 observers, there was an inverse relationship between repeatability and time spent marking images, and no correlation with image quality or curve magnitude. Kappa values for the variability of the King et al classification averaged 0.85 (intraobserver). CONCLUSIONS Variability of Cobb measurements compares favorably with previously published series. The classification was more reliable than achieved by unassisted observers evaluating the same radiographs. The same principles may be applicable to other radiographic measurement and evaluation procedures.
منابع مشابه
A Semi-Automatic Algorithm for Estimating Cobb Angle
Background: Scoliosis is the most common type of spinal deformity. A universal and standard method for evaluating scoliosis is Cobb angle measurement, but several studies have shown that there is intra- and inter- observer variation in measuring cobb angle manually.Objective: Develop a computer- assisted system to decrease operator-dependent errors in Cobb angle measurement.Methods: The spinal ...
متن کاملCobb Angle Measurement of Scoliosis Using Computer Measurement of Digitally Acquired Radiographs-Intraobserver and Interobserver Variability
STUDY DESIGN We evaluated computer assisted digital measurement of radiographic parameters in patients with idiopathic scoliosis. PURPOSE To assess the reliability of digital measurements. OVERVIEW OF LITERATURE Various authors analyzed scoliotic deformities by conventional radiographs, but very few studies have addressed the reliability of digital radiographic measurement using computer so...
متن کاملA Novel Computer-Aided Method to Evaluate Scoliosis Curvature using Polynomial Math Function
Background: Scoliosis is a health problem that causes a side-to-side curvature in the spine. The curvature may have an “S” or “C” shape. To evaluate scoliosis, the Cobb angle has been commonly used. However, digital image processing allows the Cobb angle to be obtained easily and quickly, several researchers have determined that Cobb angle contains high variations (errors) in the measurements. ...
متن کاملComputer-Assisted Radiographic Calculation of Spinal Curvature in Brachycephalic “Screw-Tailed” Dog Breeds with Congenital Thoracic Vertebral Malformations: Reliability and Clinical Evaluation
The objectives of this study were: To investigate computer-assisted digital radiographic measurement of Cobb angles in dogs with congenital thoracic vertebral malformations, to determine its intra- and inter-observer reliability and its association with the presence of neurological deficits. Medical records were reviewed (2009-2013) to identify brachycephalic screw-tailed dog breeds with radiog...
متن کاملIdentifying sources of variability in scoliosis classification using a rule-based automated algorithm.
STUDY DESIGN Use of a rule-based automated algorithm to determine sources of variability in radiographic classification. OBJECTIVES To determine whether unambiguous rules encoded in a computer program would ensure reliable classification. SUMMARY OF BACKGROUND DATA Reliability problems have been identified in classifications used in surgical planning for patients with thoracic idiopathic sc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Spine
دوره 31 6 شماره
صفحات -
تاریخ انتشار 2006