Hybrid Prospective & Retrospective Head Motion Correction System to Mitigate Cross-Calibration Errors

نویسندگان

  • M. Aksoy
  • C. Forman
  • M. Straka
  • T. Çukur
  • S. J. Holdsworth
  • S. T. Skare
  • J. M. Santos
  • J. Hornegger
  • R. Bammer
چکیده

INTRODUCTION – Correction of head motion artifacts is essential for clinically acceptable image quality. This is especially important for long scans, such as DTI, fMRI, and high-resolution structural scans. Prospective motion-correction using stereovision systems [1,2] have been suggested to perform real-time head motion-correction without necessitating the acquisition of additional MR-based navigators. This enables real-time tracking of head motion with little or no changes to the pulse sequence. However, the accuracy requirements on the motion tracking of such systems necessitate long and meticulous scanner-camera cross-calibration times [1,2], which may not be available during clinical routines. In this study, we combine monovision-based, MR-compatible prospective motion-correction system [3] with retrospective motion-correction to mitigate residual artifacts that remain in the image after prospective motion-correction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved Prospective Optical Motion Correction for DTI Using an Extended-Field-of-View and Self-Encoded Marker

INTRODUCTION – Due to the prolonged acquisition time, correction for rigid-body motion artifacts is essential for diagnostic image quality in DTI. Prospective motion correction using a monovision camera system and a checkerboard marker has previously been used to correct for rigid head motion artifacts [1,2]. In this study, we use a more sophisticated marker design to improve prospective optica...

متن کامل

Comparison of Image-Based Retrospective and Optical Prospective Motion Correction for Diffusion Tensor Imaging

INTRODUCTION Correction of rigid head motion correction is important in diffusion tensor imaging because of the long acquisition times. Rigid head correction can be carried out either retrospectively prospectively. In this study, we compared the effectiveness of these two approaches in correcting motion artifacts in DTI. Retrospective correction was based on MR-based navigator data (1-3), whils...

متن کامل

Fast Cross-Calibration Between MR Scanner and Optical System for Prospective Motion Correction

INTRODUCTION – Utilization of stereovision [1,2] or monovision [3] systems have been suggested as a way to perform rigid head motion correction for MRI. Since no additional MR-based navigator acquisition is required, these systems can be used with any scanning protocol with only minimal changes to the sequence. However, the usability of optical systems in clinical practice has so far been limit...

متن کامل

Prospective Head Movement Correction for High-resolution MRI Using a Single Camera

Introduction The image quality of brain MRI scans can be compromised by head motion. Prospective motion correction based on external tracking systems has been proposed to ameliorate this issue. Stereo optical tracking systems have been shown to give good real-time motion correction with reasonable accuracy [1,2]. However, the accurate calibration for the stereo system as well as the calibration...

متن کامل

Head pose prediction for prospectively-corrected EPI during rapid subject motion

INTRODUCTION Prospective motion correction using an external tracking device is an effective technique for motion correction in fMRI [1]. It has advantages over image-based correction methods [2], which require full volume coverage to compute motion parameters in a full six degrees of freedom (6DOF). The ultimate goal of this project is to use prospective correction to perform fMRI experiments ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009