Reliability and validity of noninvasive imaging of internal carotid artery pseudo-occlusion.

نویسندگان

  • G Fürst
  • A Saleh
  • F Wenserski
  • J Malms
  • M Cohnen
  • A Aulich
  • T Neumann-Haefelin
  • M Schroeter
  • H Steinmetz
  • M Sitzer
چکیده

BACKGROUND AND PURPOSE Our study evaluated noninvasive tests for the diagnosis of atheromatous internal carotid artery (ICA) pseudo-occlusion. METHODS Twenty patients (17 men, 3 women; mean age +/-SD, 64.3+/-11.6 years) with angiographically proven atheromatous ICA pseudo-occlusion (20 vessels) were prospectively examined with MR angiography (MRA; 2D and 3D time-of-flight techniques), color Doppler-assisted duplex imaging (CDDI) and power-flow imaging (PFI) with and without an intravenous ultrasonic contrast agent. As a control group, 13 patients (13 men; mean+/-SD age, 63.0+/-9.0 years) with angiographically proven ICA occlusion (13 vessels) were studied with the same techniques. For the determination of interobserver agreement (kappa statistics), the findings of each diagnostic technique were read by 2 blinded and independent observers who were not involved in patient recruitment and initial data acquisition. Specificity and sensitivity were calculated for all noninvasive techniques (observer consensus) in comparison to the standard of reference (intra-arterial angiography). RESULTS Interobserver reliabilities were kappa=0.86 for intra-arterial angiography, kappa=0.90 for unenhanced CDDI, kappa=0. 93 for enhanced CDDI, kappa=0.93 for unenhanced PFI, kappa=1.0 for enhanced PFI, kappa=0.93 for 2D MRA, and kappa=0.77 for 3D MRA, respectively (P<0.0001). Specificities and sensitivities were 0.92 and 0.70 for unenhanced CDDI, 0.92 and 0.83 for enhanced CDDI, 0.92 and 0.95 for unenhanced PFI, 1.0 and 0.94 for enhanced PFI, 1.0 and 0.65 for 2D MRA, and 0.89 and 0.47 for 3D MRA, respectively. CONCLUSIONS Advanced ultrasonographic techniques, especially PFI (with only 1 false-positive diagnosis of occlusion in the present series), can provide reliable and valid data to differentiate between ICA pseudo-occlusion and complete occlusion. In contrast, time-of-flight MRA at its present state is not capable of predicting minimal residual flow within a nearly occluded ICA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform

Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...

متن کامل

Carotid angioplasty and stenting in a patient with high grade stenosis of Internal Carotid Artery associated with both vertebral arteries and contralateral carotid occlusion

Severe internal carotid artery (ICA) stenosis is a common cause of cerebrovascular accident (CVA) in middle-aged patients. Contralateral carotid occlusion (CCO) in patients with severe ICA stenosis is associated with high risk of CVA. Carotid endarterectomy (CEA) is associated with more complications in patients with CCO than those without CCO. In this study, we present the case of a 61-year-ol...

متن کامل

Atheromatous pseudo-occlusion of the internal carotid artery.

Between 1978 and 1988, the diagnosis of atheromatous pseudo-occlusion of the internal carotid artery was made in 34 patients by angiography. Results of noninvasive tests were abnormal in 33 of the 34 patients examined. Twenty-five patients had carotid endarterectomy, and the other nine were treated medically. Four of the 34 patients (12%) had significant complications, two related to angiograph...

متن کامل

Between-method correlation in quantifying internal carotid stenosis.

BACKGROUND AND PURPOSE The degree of internal carotid stenosis has emerged as the most important predictor of ischemic stroke in extracranial carotid artery disease. The purpose of this study was to assess the validity of the noninvasive techniques for quantifying internal carotid stenosis with respect to the accepted standard of intra-arterial angiography. METHODS We measured the maximum per...

متن کامل

ارزیابی و بررسی نتایج حاصل از داپلر فراصوتی در مقایسه با آنژیوگرافی تفریقی دیجیتال در تشخیص تنگ شدگیهای شریان کاروتید داخلی

Introduction: Digital Subtraction Angiography (DSA) is the standard method for detection of carotid artery stenosis. This technique has high radiation dose. With the progress of imaging techniques, noninvasive or minimally invasive methods like the CT angiography, MR angiography and ultrasonography with Doppler or Duplex mode were applicable. This study aimed to evaluate and assesse the results...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 30 7  شماره 

صفحات  -

تاریخ انتشار 1999