Visual acuity testing. From the laboratory to the clinic
نویسندگان
چکیده
The need for precision in visual acuity assessment for low vision research led to the design of the Bailey-Lovie letter chart. This paper describes the decisions behind the design principles used and how the logarithmic progression of sizes led to the development of the logMAR designation of visual acuity and the improved sensitivity gained from letter-by-letter scoring. While the principles have since been adopted by most major clinical research studies and for use in most low vision clinics, use of charts of this design and application of letter-by-letter scoring are also important for the accurate assessment of visual acuity in any clinical setting. We discuss the test protocols that should be applied to visual acuity testing and the use of other tests for assessing profound low vision when the limits of visual acuity measurement by letter charts are reached.
منابع مشابه
Subcutaneous Erythropoietin Reverses Optic Neuropathy Induced by Methanol Poisoning: Three case reports
Background: Methanol is a highly toxic alcohol and causes such severe side effects as CNS depression, blindness, acute renal failure and even death. Methods: Patients were three male referrals (aged 29-56 years) to the poisoning center at Taleghani Hospital, Urmia, Iran, in 2020. They had unknowingly ingested methanol. Their chief problems were bilateral blindness and metabolic acidosis. Upon ...
متن کاملEvaluation of Optical Coherence Tomography Angiography Findings in Patients with Branch Retinal Vein Occlusion
Purpose: To analyze the correlation of optical coherence tomography angiography (OCTA) findings with visual acuity (VA) in patients with branch retinal vein occlusion (BRVO). Methods: This cross-sectional study was performed on 20 eyes of 20 patients with unilateral BRVO involving the macula referred to the ophthalmology clinic of Rassoul Akram Hospital. OCTA imaging was conducted for all patie...
متن کاملA Quantitative Investigation on the Effect of Edge Enhancement for Improving Visual Acuity at Different Levels of Contrast
Background: The major limitation in human vision is refractive error. Auxiliary equipment and methods for these people are not always available. In addition, limited range of accommodation in adult people when switching from a far point to a near point is not simply possible. In this paper, we are looking for solutions to use the facilities of digital image processing and displaying to improve ...
متن کاملبررسی مقایسهای حدت بینایی و حساسیت به کنتراست در رانندگان مراجعهکننده به درمانگاه چشم بیمارستان فرشچیان همدان
Background and Objective: Car accidents are the second leading cause of mortality in Iran. For safe driving, drivers require minimum acceptable visual acuity. In Iran, the accepted routine test to take driving license is Snellen vision chart, which is not adequate for visual acuity determination in real and natural environment. It seems that introducing a more sensitive and specific screening t...
متن کاملA rare ophthalmologic disorder: Gyrate atrophy with sparse hair
Gyrate atrophy (GA) is a rare, progressive metabolic choroid and retinal degeneration that results from a deficiency of the pyridoxal phosphate-dependent mitochondrial matrix enzyme ornithine aminotransferase. Here, we report the case of a 40-yearold woman who presented with a gradual decline in visual acuity since puberty, along with a history of high myopia and cataract surgery. She was admit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Vision Research
دوره 90 شماره
صفحات -
تاریخ انتشار 2013