Tomographic Reflection to Merge Ultrasound Images with Direct Vision

نویسندگان

  • George D. Stetten
  • Vikram S. Chib
  • Robert J. Tamburo
چکیده

Tomographic reflection is a method that may be used to merge the visual outer surface of a patient with a simultaneous ultrasound scan of the patient’s interior. The technique combines a flat-panel monitor with a halfsilvered mirror such that the image on the monitor is reflected precisely at the proper location within the patient. In this way, the ultrasound image is superimposed in real time on the view of the patient along with the operator's hands and any invasive tools in the field of view. Instead of looking away at an ultrasound monitor, the operator can manipulate needles and scalpels with direct hand-eye coordination. Invasive tools are visible up to where they enter the skin, permitting natural visual extrapolation to targets in the ultrasound slice. Tomographic reflection is independent of viewer location, requires no special apparatus to be worn by the operator, nor any registration of the patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Guidance of retrobulbar injection with real-time tomographic reflection.

OBJECTIVE Retrobulbar and peribulbar injections are common ophthalmologic procedures used to deliver anesthetics and other medications for ophthalmic therapy and surgery. These injections, typically performed without any type of guidance, can lead to complications that are rare but visually devastating. The needle may penetrate the optic nerve, perforate the globe, or disperse toxic quantities ...

متن کامل

Real Time Tomographic Reflection with Ultrasound: Stationary and Hand-Held Implementations

Our objective is to permit in situ visualization of ultrasound images so that direct hand-eye coordination can be employed during invasive procedures. A method is presented that merges the visual outer surface of a patient with a simultaneous ultrasound scan of the patient's interior. The method combines a flat-panel monitor with a half-silvered mirror such that the image on the monitor is refl...

متن کامل

Magnified Real-Time Tomographic Reflection

Real Time Tomographic Reflection (RTTR) permits in situ visualization of ultrasound images so that direct hand-eye coordination can be employed during invasive procedures. The method merges the visual outer surface of a patient with a simultaneous ultrasound scan of the patient’s interior. It combines a flat-panel monitor with a half-silvered mirror such that the image on the monitor is reflect...

متن کامل

C-Mode Real Time Tomographic Reflection for a Matrix Array Ultrasound Sonic Flashlight

RATIONALE AND OBJECTIVES Real-time tomographic reflection (RTTR) permits in situ visualization of tomographic images so that natural hand-eye coordination can be used directly during invasive procedures. The method uses a half-silvered mirror to merge the visual outer surface of the patient with a simultaneous scan of the patient's interior without requiring a head-mounted display or tracking. ...

متن کامل

Extending the Sonic Flashlight to Real Time Tomographic Holography

Real Time Tomographic Reflection (RTTR) permits in situ visualization of tomographic images, enabling natural hand-eye coordination to guide invasive procedures. The method as originally developed uses a halfsilvered mirror to merge the visual outer surface of the patient with a simultaneous scan of the patient’s interior. A viewpoint-independent virtual image is reflected precisely into the co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000