O2-CO2 diagram as a tool for comprehension of blood gas abnormalities.
نویسندگان
چکیده
Sathya Subramani, Praghalathan Kanthakumar, Delinda Maneksh, Anita Sidharthan, Shoma V. Rao, Vinodh Parasuraman, and Elizabeth Tharion Department of Physiology and Surgical Intensive Care Unit, Christian Medical College, Vellore, Tamilnadu; Department of Physiology, Dr. Somervell Memorial C.S.I. Medical College and Hospital, Karakonam, Kerala; and Department of Physiology, Travancore Medical College, Kerala, India
منابع مشابه
Estimating the second virial coefficients of some real gas mixtures and related thermodynamic views
Using the Gaussian 2003 software and MP2 /6 – 311+ G method for the C2H4 : O2, CO:Cl2 andCO2:CO2 pairs and MP2/6-311++G** method for the CO2:H2O pair and B3lyp/6-31G methodfor the O2:O2 pair the optimized interaction energies between two considered pair molecules ofstudied gases(C2H4:O2, CO:Cl2, CO2:H2O, O2:O2 and CO2:CO2 pairs) as a function of thedistances between the centers of two considere...
متن کاملOptimization of parameters affecting separation of gas mixture of O2, N2, CO2 and CH4 by PMP membrane modified with TiO2, ZnO and Al2O3 nanoparticles
The application of membranes in various industries is one of the most urgent needs to reduce energy consumption and environmental pollutants as well as low investment costs in the process of separation. In this investigation, the optimization of effective parameters for separation of gas mixture of CH4, CO2, O2 and N2 is studied by modified poly(4-met...
متن کاملThe effect of CO2- and O2-gas mixtures on laser Doppler measured cochlear and skin blood flow in guinea pigs.
The effects of carbogen (5% CO2: 95% O2) 10% CO2-in-air and 100% O2 on cochlear blood flow (CBF), skin blood flow (SBP), blood pressure (BP) and arterial blood gases were investigated in the anesthetized, respired or self-respiring guinea pig. In respired animals, CBF and SBF were increased with carbogen and 10% CO2-in-air and decreased with O2. BP was elevated with each gas. In freely breathin...
متن کاملWelding of 304L Stainless Steel to 409 Stainless Steel with GMAW Process Using ER316LSi and ER309LMo Filler Metals
Dissimilar welding of AISI 304L austenitic stainless steel to AISI 409 ferritic stainless steel with GMAW process usingtwo Ar-O2 and Ar-CO2 shielding gas mixtures was studied. ER316LSi and ER309LMo filler metals were chosen by considering 5 and 15% delta ferrite according to the Schaeffler equations and diagram. Based on the observations, both filler metals accompanied by Ar-2%O2 shielding gas ...
متن کاملWelding of 304L Stainless Steel to 409 Stainless Steel with GMAW Process Using ER316LSi and ER309LMo Filler Metals
Dissimilar welding of AISI 304L austenitic stainless steel to AISI 409 ferritic stainless steel with GMAW process usingtwo Ar-O2 and Ar-CO2 shielding gas mixtures was studied. ER316LSi and ER309LMo filler metals were chosen by considering 5 and 15% delta ferrite according to the Schaeffler equations and diagram. Based on the observations, both filler metals accompanied by Ar-2%O2 shielding gas ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Advances in physiology education
دوره 35 3 شماره
صفحات -
تاریخ انتشار 2011