BACKGROUND Electroporation is gaining its importance in everyday clinical practice of cancer treatment. For its success it is extremely important that coverage of the target tissue, i.e. treated tumor, with electric field is within the specified range. Therefore, an efficient tool for the electric field monitoring in the tumor during delivery of electroporation pulses is needed. The electric field can be reconstructed by the magnetic resonance electric impedance tomography method from current density distribution data. In this study, the use of current density imaging with MRI for monitoring current density distribution during delivery of irreversible electroporation pulses was demonstrated. METHODS Using a modified single-shot RARE sequence, where four 3000 V and 100 μs long pulses were included at the start, current distribution between a pair of electrodes inserted in a liver tissue sample was imaged. Two repetitions of the sequence with phases of refocusing radiofrequency pulses 90° apart were needed to acquire one current density image. For each sample in total 45 current density images were acquired to follow a standard protocol for irreversible electroporation where 90 electric pulses are delivered at 1 Hz. RESULTS Acquired current density images showed that the current density in the middle of the sample increased from first to last electric pulses by 60%, i.e. from 8 kA/m2 to 13 kA/m2 and that direction of the current path did not change with repeated electric pulses significantly. CONCLUSIONS The presented single-shot RARE-based current density imaging sequence was used successfully to image current distribution during delivery of short high-voltage electric pulses. The method has a potential to enable monitoring of tumor coverage by electric field during irreversible electroporation tissue ablation.
منابع مشابه
Finite Element Analysis of Tissue Conductivity during High-frequency and Low-voltage Irreversible Electroporation
Introduction: Irreversible electroporation (IRE) is a process in which the membrane of the cancer cells are irreversibly damaged with the use of high-intensity electric pulses, which in turn leads to cell death. The IRE is a non-thermal way to ablate the cancer cells. This process relies on the distribution of the electric field, which affects the pulse amplitude, width, and electrical conducti...
متن کاملThe importance of electric field distribution for effective in vivo electroporation of tissues.
Cells exposed to short and intense electric pulses become permeable to a number of various ionic molecules. This phenomenon was termed electroporation or electropermeabilization and is widely used for in vitro drug delivery into the cells and gene transfection. Tissues can also be permeabilized. These new approaches based on electroporation are used for cancer treatment, i.e., electrochemothera...
متن کاملSynergistic Combination of Electrolysis and Electroporation for Tissue Ablation
Electrolysis, electrochemotherapy with reversible electroporation, nanosecond pulsed electric fields and irreversible electroporation are valuable non-thermal electricity based tissue ablation technologies. This paper reports results from the first large animal study of a new non-thermal tissue ablation technology that employs "Synergistic electrolysis and electroporation" (SEE). The goal of th...
متن کاملElectric current density imaging of mice tumors.
The use of electric current density imaging (CDI) to map spatial distribution of electric currents through tumors is presented. Specifically, a method previously tested on phantoms was implemented in vivo and in vitro for mapping electric current pulses of the same order of magnitude (j approximately 2500 A/m2) as in electrochemotherapy through T50/80 mammary carcinomas, B-16 melanomas and SA-1...
متن کاملTissue heating during tumor ablation with irreversible electroporation
Exposing biological cells to sufficiently strong external electric fields causes electroporation of cell membranes, i.e. occurrence of transient or permanent permeable pathways between the interior and exterior of the cell. Electroporation can be used to introduce various molecules into cells (reversible electroporation) or to kill cells (irreversible electroporation), which can in turn be used...