Healthcare Utilization and Expenditures Associated With Appropriate and Inappropriate Implantable Defibrillator Shocks.
نویسندگان
چکیده
BACKGROUND In patients with implantable cardioverter-defibrillators, healthcare utilization (HCU) and expenditures related to shocks have not been quantified. METHODS AND RESULTS We performed a retrospective cohort study of patients with implantable cardioverter-defibrillators identified from commercial and Medicare supplemental claims databases linked to adjudicated shock events from remote monitoring data. A shock event was defined as ≥1 spontaneous shocks delivered by an implanted device. Shock-related HCU was ascertained from inpatient and outpatient claims within 7 days following a shock event. Shock events were adjudicated and classified as inappropriate or appropriate, and HCU and expenditures, stratified by shock type, were quantified. Of 10 266 linked patients, 963 (9.4%) patients (61.3±13.6 years; 81% male) had 1885 shock events (56% appropriate, 38% inappropriate, and 6% indeterminate). Of these events, 867 (46%) had shock-related HCU (14% inpatient and 32% outpatient). After shocks, inpatient cardiovascular procedures were common, including echocardiography (59%), electrophysiology study or ablation (34%), stress testing (16%), and lead revision (11%). Cardiac catheterization was common (71% and 51%), but percutaneous coronary intervention was low (6.5% and 5.0%) after appropriate and inappropriate shocks. Expenditures related to appropriate and inappropriate shocks were not significantly different. CONCLUSIONS After implantable cardioverter-defibrillator shock, related HCU was common, with 1 in 3 shock events followed by outpatient HCU and 1 in 7 followed by hospitalization. Use of invasive cardiovascular procedures was substantial, even after inappropriate shocks, which comprised 38% of all shocks. Implantable cardioverter-defibrillator shocks seem to trigger a cascade of health care. Strategies to reduce shocks could result in cost savings.
منابع مشابه
Association between myocardial substrate, implantable cardioverter defibrillator shocks and mortality in MADIT-CRT.
OBJECTIVE The aim of the present study was to assess a possible association between myocardial substrate, implantable cardioverter defibrillator (ICD) shocks, and subsequent mortality. METHODS Within the multicentre automatic defibrillator implantation trial-cardiac resynchronization therapy (MADIT-CRT) population (n = 1790), we investigated the association between myocardial substrate, ICD s...
متن کاملPrognostic impact of inappropriate defibrillator shocks in a population cohort.
BACKGROUND There is a relative paucity of data linking inappropriate implantable cardioverter-defibrillator (ICD) shocks to adverse clinical outcomes. OBJECTIVE To examine the association between inappropriate ICD shocks and mortality or heart transplantation in a large population cohort. DESIGN, SETTING, PATIENTS A cohort study which included all subjects who underwent ICD implantation bet...
متن کاملOutcome of implantable cardioverter defibrillators in adults with congenital heart disease: a multi-centre study.
AIMS To investigate outcome and complications of implantable cardioverter defibrillators (ICDs) in adults with congenital heart disease (CHD) and to identify predictors of (in-) appropriate shocks. METHODS AND RESULTS Sixty-four CHD patients >/= 18 years at first ICD implantation [63% tetralogy of Fallot (TOF) and age at implantation 37 +/- 13 years] were identified using the Dutch adult CHD ...
متن کاملImplantable cardioverter-defibrillator shocks: epidemiology, outcomes, and therapeutic approaches.
IMPORTANCE Implantable cardioverter-defibrillators (ICDs) have revolutionized the approach to the prevention of sudden cardiac death and are commonly used in a wide range of high-risk patients, including the large population of patients with severe left ventricular systolic dysfunction. The benefit of these devices derives from their therapies, including both antitachycardia pacing and high-ene...
متن کاملMinimizing inappropriate or "unnecessary" implantable cardioverter-defibrillator shocks: appropriate programming.
Life-saving shocks are the raisons d’être of implantable cardioverter-defibrillators (ICDs). Paradoxically, shocks also cause much of the morbidity associated with ICDs. Consistently, shocks reduce quality of life,1,2 and rarely, they may cause proarrhythmia.3,4 Additionally, shocks have been reported to be associated with excess mortality.5 Experts disagree about whether shocks are responsible...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular quality and outcomes
دوره 10 2 شماره
صفحات -
تاریخ انتشار 2017