Vacuum-assisted apical suction devices induce passive electrical changes consistent with myocardial ischemia during off-pump coronary artery bypass graft surgery.

نویسندگان

  • Roger Dzwonczyk
  • Carlos L del Rio
  • Chittoor Sai-Sudhakar
  • John H Sirak
  • Robert E Michler
  • Benjamin Sun
  • Nicole Kelbick
  • Michael B Howie
چکیده

OBJECTIVE Off-pump coronary artery bypass graft surgery is common therapy to completely revascularize diseased hearts. In order to graft posterior arteries in this procedure, the heart must be lifted from the chest cavity and manipulated to expose the surgical field using an apical suction device. This suction device may cause unwanted myocardial ischemia. METHODS In this observational study, we measured myocardial electrical impedance, a parameter that responds to myocardial ischemia, as well as ST-segment changes during off-pump coronary artery bypass graft surgery in 12 patients with two-vessel coronary artery disease undergoing revascularisation of the left anterior descending and the posterior descending coronary arteries. During the posterior descending artery revascularisation phase of the procedure the apical suction device was oriented over the electrodes used to measure myocardial electrical impedance, thus allowing us the opportunity to assess myocardial ischemia in this region of the heart. RESULTS In these 12 patients, myocardial electrical impedance progressively increased under the suction device during posterior coronary artery revascularisation, suggesting that myocardial ischemia developed in this region of the myocardium. ST-segment changes were negligible while the heart was vertically displaced (and the suction device attached), but increased immediately when the heart was returned to the neutral anatomical position. CONCLUSION Our data suggest that the apical suction device may cause ischemia while the heart is vertically displaced and electrically disconnected from the body. Under these conditions, ST-segment changes may not detect myocardial ischemia. Myocardial electrical impedance has the potential to reliably detect intraoperative myocardial ischemia under these circumstances.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Deep pericardial traction suture versus vacuum-assisted apical suction to expose the posterior wall of the heart in off-pump coronary artery bypass: a prospective, randomized study.

BACKGROUND Displacement of the heart to expose the posterior vessels during off-pump coronary artery bypass (OPCAB) may cause hemodynamic instability. Deep pericardial traction suture (DPTS) and vacuum-assisted apical suction (VAS) with the Starfish positioning device help to provide good exposure without relevant hemodynamic changes. Our aim was to compare these two methods in patients undergo...

متن کامل

مقایسه‌ی نتایج استفاده از شانت داخل عروق کرونر در عمل بای‌پس عروق کرونر بدون پمپ نسبت به عدم استفاده از آن

Background and Objective: Off pump coronary artery bypass graft can be done with or without using intracoronary shunt. We have compared these two methods in early postoperative period, in this study. Materials and Methods: 208 candidate patients for off pump coronary artery bypass graft were devided in to two groups randomly for using intracoronary shunt or not. Variables including peri and pos...

متن کامل

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

Off-Pump Versus On-Pump Coronary Artery Bypass Graft Surgery, prospective cohort study

Introduction: Coronary artery bypass grafting is a surgical operation that bypasses atherosclerotic coronary vessels and restores blood flow to the ischemic zone of hearts. And two different conventional methods are ON-pump CABG, and Off-pump CABG.  Altogether, the efficacy and safety of these two types of surgical procedures are still under debate. In this study, we aim to com...

متن کامل

Mechanisms of hemodynamic changes during off-pump coronary artery bypass surgery.

PURPOSE To describe the mechanisms of hemodynamic changes during off-pump coronary artery bypass graft surgery (OP-CABG). SOURCE Pertinent medical literature in the English and French languages was identified through a Medline computerized literature search and a manual search of selected articles, using off-pump coronary artery surgery, beating heart surgery, hemodynamic, and transesophageal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 30 6  شماره 

صفحات  -

تاریخ انتشار 2006