The optimal timing of baseline radiostereometric analysis of uncemented press fit cups.

نویسندگان

  • O Wolf
  • J Milbrink
  • S Larsson
  • P Mattsson
  • H Mallmin
چکیده

BACKGROUND AND AIMS The baseline radiostereometric analysis (RSA) is usually performed during the first postoperative week. We investigated the micromotion of two uncemented press fit acetabular cups during the first week after total hip arthroplasty. MATERIAL AND METHODS All study patients had unilateral osteoarthritis of the hip and received an uncemented THA combination consisting of a CLS stem and either an Allofit or an Interop acetabular cup. The study group consisted of 24 patients who underwent RSA within 1 hour after skin closure, and at 1 and 7 days after surgery. RESULTS The upper limit of the 95% confidence interval for micromotion was less than or close to the precision of the method for all studied directions during the first week after surgery. Mean values indicate proximal and medial translation of the uncemented cup at one week. CONCLUSIONS We found only minimal micromotion, barely above the precision limit, measured as medial and proximal translations of these uncemented cups. This indicates that the first postoperative RSA measurement following a primary THA with an uncemented press fit ace-tabular cup should be made as early as possible after the first postoperative day.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Equally good fixation of cemented and uncemented cups in total trapeziometacarpal joint prostheses

BACKGROUND AND PURPOSE Cup failure is a recognized problem in total trapeziometacarpal (TM) joint prostheses; it may be related to poor fixation, which can be revealed by radiostereometric analysis (RSA). We compared the early implant migration of cemented trapezium cups to that of uncemented screw cups. PATIENTS AND METHODS In a prospective, parallel-group, randomized patient-blinded clinica...

متن کامل

No effect of additional screw fixation of a cementless, all-polyethylene press-fit socket on migration, wear, and clinical outcome

Background and purpose - Additional screw fixation of the all-polyethylene press-fit RM cup (Mathys) has no additional value for migration, in the first 2 years after surgery. However, the medium-term and long-term effects of screw fixation remain unclear. We therefore evaluated the influence of screw fixation on migration, wear, and clinical outcome at 6.5 years using radiostereometric analysi...

متن کامل

Polyethylene wear in uncemented acetabular components.

We measured polyethylene wear in 231 porous-coated uncemented acetabular cups. We divided the hips into two groups according to the fixation of the femoral component, by cementing (n = 97) or press-fit (n = 134). Follow-up was from three to five years. The patients in two sub-groups were matched for weight, diagnosis, sex, age and length of follow-up. The linear wear rate of cups articulated wi...

متن کامل

Increased migration of uncemented acetabular cups in female total hip arthroplasty patients with low systemic bone mineral density

BACKGROUND AND PURPOSE Low bone mineral density (BMD) may jeopardize the initial component stability and delay osseointegration of uncemented acetabular cups in total hip arthroplasty (THA). We measured the migration of uncemented cups in women with low or normal BMD. PATIENTS AND METHODS We used radiostereometric analysis (RSA) to measure the migration of hydroxyapatite-coated titanium alloy...

متن کامل

Unsatisfactory results with the cementless Omnifit acetabular component due to polyethylene and severe osteolysis.

A high incidence of acetabular osteolysis (43%), associated with osteolytic lesions in the proximal femur (22.6%) and leading to a high revision rate, was experienced with the Omnifit total hip prosthesis. We reviewed the clinical and radiological results with 429 Omnifit total hips in 356 patients after a mean follow-up of 60 months. Time to revision and wear of the polyethylene liner with dif...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Scandinavian journal of surgery : SJS : official organ for the Finnish Surgical Society and the Scandinavian Surgical Society

دوره 99 4  شماره 

صفحات  -

تاریخ انتشار 2010