Electrical Impedance Tomography (eit) Method for Saturation Determination
نویسندگان
چکیده
3D Electrical Impedance Tomography (EIT) is an alternative to the traditional CT scan technique that has been used to measure saturation distribution within a rock core. The primary motivation for investigating EIT is the applicability to high pressure, high temperature geothermal reservoir conditions, which would require a metal core holder, therefore eliminating the use of the CT scan technique. Secondary advantages of the EIT technique are that it is an inexpensive, practical, compact, and safe alternative to the CT scan. The initial EIT device presented here instrumented a Berea sandstone core with 48 electrodes attached in three rings of 16. The core is open to the atmosphere and saturation occurs by natural imbibition. The resistivity measurements are conducted by applying a direct current pulse and using the 4-wire resistance technique over all electrodes. This resulted in a data set that embodies the resistivity distribution within the core. Processing of this data set results in the reconstruction of the resistivity distribution, which is the saturation distribution. The processing was accomplished by utilizing the EIDORS toolkit developed for MATLAB. The toolkit was required due to the nature of EIT being nonlinear and an ill-posed problem. The EIDORS application utilizes a finite element model for forward calculations and a regularized nonlinear solver to obtain a unique and stable inverse solution. (Polydorides et al. 2002) It was found that EIT can detect changes in the core’s resistivity distribution quickly and with relatively good accuracy. However, currently the diffusive nature of EIT makes the reliable detection of sharp saturation fronts difficult, but not impossible. Therefore future efforts are being applied to increase resolution and quantify accuracy. INTRODUCTION The concept of measuring the saturation distribution in a core using ERT was described in a paper by Van Weereld, et al. (2001). The paper showed that EIT techniques were able to image a two-phase system (oil and brine). However the techniques shown in the paper did not convert resistivity images to saturation, or validate their results against other methods. Therefore we have developed an apparatus to investigate the feasibility of using EIT to measure geothermal core saturation.
منابع مشابه
Applications of Electrical Impedance Tomography in Neurology
Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...
متن کاملThe Effect of Gold Nanoparticle on Electrical Impedance of Tissue on Low Frequency Ranges
Introduction: Electrical impedance of tissues on low frequencies includes useful information about functional and structural changes in tissues. This property is used in Electrical Impedance Tomography (EIT) imaging modality for the detection of lesions in tissues.Objective: The goal of this article is to study changes in electrical impedance of tissues in the presence of gold nanoparticles.Mat...
متن کاملEvaluation of the use of gold nanoparticle as contrast agent in electrical impedance imaging
Introduction: Electrical Impedance Tomography (EIT) is a real time and minimal invasive imaging modality for detection of lesions in tissues even when their structures show no changes. Early detection of lesion with EIT depends on difference between electrical impedance of targeted tissue and its surroundings. Therefore, finding a contrast agent for EIT that increase this diffe...
متن کاملElectrical Impedance Tomography (EIT) and Its Medical Applications: A Review
This paper reviews the principles of Electrical Impedance Tomography (EIT), different types of current patterns and reconstruction algorithms to assess its potential in medical imaging. A current injection pattern in EIT has its own current distribution profile within the subject under test. Hence, different current patterns have different sensitivity, spatial resolution and distinguishability....
متن کاملImprovement ability of EIT for Thermal monitoring during Thermal Therapy by gold nanoparticles
Introduction: To prevention the healthy tissues from irreversible damages, monitoring the temperature variation of healthy tissues is critical parameter during thermal therapies. Electrical impedance tomography (EIT) is considered as a real time imaging modality for monitoring the temperature but researches show that it suffers from low temperature resolution. In this study usi...
متن کامل