A method for determining the reference effective flow areas for mechanical heart valve prostheses: in vitro validation studies.

نویسندگان

  • R Shandas
  • J Kwon
  • L Valdes-Cruz
چکیده

BACKGROUND The anatomic opening area (AOA) is usually reported as the primary index of mechanical heart valve function. Because flow contracts immediately distal to an orifice as a result of the vena contracta effect, AOA may not be a good measure of true effective flow area. METHODS AND RESULTS Laser flow imaging was used to visualize the contraction in the jet flow stream as it passed through bileaflet mechanical valves under steady and pulsatile conditions. Such visualization allowed clear measurement of the individual vena contracta areas (VCAs) of the 3 valve orifices. VCAs for side orifices were larger (94+/-2% of AOA) than those through the central orifice (34+/-8%). Formation of large radial vortices around the leaflet tips constricted the central orifice flow stream and appeared to be the main reason for smaller central VCA. Total VCA remained constant until approximately 0.5 orifice diameters ( approximately 1.0 cm) downstream, beyond which cross-sectional area increased as a result of entrainment of receiving chamber flow. Total VCA was larger for steady flow (89.6+/-2.7% of AOA) than for pulsatile flow (76.3+/-5.0% of AOA). CONCLUSIONS This study further clarifies flow dynamics through bileaflet mechanical valves and provides previously unavailable reference information on VCAs for these valves. Such information should aid clinicians in explaining Doppler-derived and catheter-measured pressure discrepancies, validating clinical techniques for quantifying effective flow areas, and optimizing valve size for implantation. The method should also be useful for comparative studies of different valve designs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of heart valve prostheses on phase contrast flow measurements in Cardiovascular Magnetic Resonance – a phantom study

BACKGROUND Cardiovascular Magnetic Resonance is often used to evaluate patients after heart valve replacement. This study systematically analyses the influence of heart valve prostheses on phase contrast measurements in a phantom trial. METHODS Two biological and one mechanical aortic valve prostheses were integrated in a flow phantom. B0 maps and phase contrast measurements were acquired at ...

متن کامل

Assessment of small-diameter aortic mechanical prostheses: physiological relevance of the Doppler gradient, utility of flow augmentation, and limitations of orifice area estimation.

BACKGROUND Noninvasive assessment of functionally stenotic small-diameter aortic mechanical prostheses is complicated by theoretical constraints relating to the hemodynamic relevance of Doppler-derived transprosthetic gradients. To establish the utility of Doppler echocardiography for evaluation of these valves, 20-mm Medtronic Hall and 19-mm St Jude prostheses were studied in vitro and in vivo...

متن کامل

Update of the European standards for inactive surgical implants in the area of heart valve prostheses.

OBJECTIVE The approval of a heart valve for the European market takes place in accordance with European and international standards. A new version of the EN Standards was published in June 2006, which responded to different technical innovations in the area of heart valve technology. This work outlines the differences between the new EN ISO 5840 (2005) and the old EN 12006-1 (1999). METHODS W...

متن کامل

Hemodynamic function of the Kay-Shiley prosthetic cardiac valve. Observations after mitral or tricuspid valve replacement.

Eighteen patients were catheterized before and nine months (average) after mitral and/or tricuspid valve replacement with the KayShiley prosthesis. In 14 patients with Kay-Shiley mitral prostheses, average cardiac index rose from 2.2 L/min/M"reoperatively to 2.8 postoperation, average left atrial mean pressure fell from 26 to 18 mm Hg, and the average left atrioventricular mean diastolic gradie...

متن کامل

The challenge of assessing heart valve prostheses by Doppler echocardiography.

The assessment of prosthetic valve function remains challenging. Echocardiography has become the key diagnostic tool not only because of its noninvasive nature and wide availability but also because of limitations inherent in alternative diagnostic techniques. Invasive evaluation is limited particularly in mechanical valves that cannot be crossed with a catheter, and in patients with both aorti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 101 16  شماره 

صفحات  -

تاریخ انتشار 2000