Development of a high-field MR-guided HIFU setup for thermal and mechanical ablation methods in small animals
نویسندگان
چکیده
BACKGROUND Thermal and mechanical high intensity focused ultrasound (HIFU) ablation techniques are in development for non-invasive treatment of cancer. However, knowledge of in vivo histopathologic and immunologic reactions after HIFU ablation is still limited. This study aims to create a setup for evaluation of different HIFU ablation methods in mouse tumors using high-field magnetic resonance (MR) guidance. An optimized MR-guided-HIFU setup could be used to increase knowledge of the different pathologic and immunologic reactions to different HIFU ablation methods. METHODS Three different HIFU treatment strategies were applied in mouse melanomas (B16): a thermal (continuous wave), a mechanical (5 ms pulsed wave), and an intermediate setting (20 ms pulsed wave) for HIFU ablation, all under MR guidance using a 7 tesla animal MR system. Histopathologic evaluation was performed 3 days after treatment. RESULTS The focus of the ultrasound transducer could accurately be positioned within the tumor under MR image guidance, without substantial damage to the surrounding tissue and skin. All mice retained complete use of the treated leg after treatment. Temperatures of >60, <50, and <44 °C were reached during thermal, intermediate, and mechanical HIFU ablation, respectively. Thermal-treated tumors showed large regions of coagulative necrosis. Tumors of both the mechanical and intermediate groups showed fractionated tissue with islands of necrosis and some pseudocysts with hemorrhage. CONCLUSION A stable small animal MR-guided HIFU setup was designed and evaluated for follow-up MR imaging and histopathologic responses of the treated tumors. This will facilitate further studies with a larger number of mice for detailed evaluation of the pathologic and immunologic response to different HIFU strategies.
منابع مشابه
Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator
Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...
متن کاملAblation of the sacroiliac joint using MR-guided high intensity focused ultrasound: a preliminary experiment in a swine model
BACKGROUND Dysfunction of the Sacroiliac Joint (SIJ) is one of the key sources of low back pain. For prolonged pain relief, some patients undergo fluoroscopic guided radio-frequency (RF) ablation of SIJ, during which a number of RF probes are inserted to create thermal lesions that disrupt the posterior sacral nerve supply. This procedure is minimally invasive, laborious, time-consuming and cos...
متن کاملNon-Invasive Targeted Peripheral Nerve Ablation Using 3D MR Neurography and MRI-Guided High-Intensity Focused Ultrasound (MR-HIFU): Pilot Study in a Swine Model
PURPOSE Ultrasound (US)-guided high intensity focused ultrasound (HIFU) has been proposed for noninvasive treatment of neuropathic pain and has been investigated in in-vivo studies. However, ultrasound has important limitations regarding treatment guidance and temperature monitoring. Magnetic resonance (MR)-imaging guidance may overcome these limitations and MR-guided HIFU (MR-HIFU) has been us...
متن کامل3D MR neurography targeted peripheral nerve ablation with MR-guided high intensity focused ultrasound (MR-HIFU): initial results of a feasibility study in a swine model
Background/introduction MR-guided HIFU is an effective treatment for metastatic bone pain through periosteal nerve ablation,[1] and is being investigated for treating back pain through facet joint denervation.[2] For peripheral neuropathy, ultrasound-guided HIFU has been investigated preclinically as a means of achieving either an irreversible conduction block to treat severe spasticity [3], or...
متن کاملEffects of magnetic resonance-guided high-intensity focused ultrasound ablation on bone mechanical properties and modeling
BACKGROUND Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a promising technique for palliative treatment of bone pain. In this study, the effects of MR-HIFU ablation on bone mechanics and modeling were investigated. METHODS A total of 12 healthy rat femurs were ablated using 10 W for 46 ± 4 s per sonication with 4 sonications for each femur. At 7 days after treatment...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 3 شماره
صفحات -
تاریخ انتشار 2015