Update on the STIS CCD CTE Performance
ثبت نشده
چکیده
STIS has been operating without major changes in its performance since the release of the STIS Instrument Handbook (IHB) version 4.1. This update provides the latest information regarding STIS performance and policies which are relevant to the preparation of Cycle 10 Phase II proposals. The items presented here may also be found on the STIS web page at http://www.stsci.edu/instruments/stis. As always, new information will be regularly described in the Spectrographs STAN (Space Telescope Analysis Newsletter) and posted on the web pages. General help or documentation may be obtained by sending email to [email protected]. This update should be used in comjunction with the STIS IHB v4.1 and the Cycle 10 Phase II Proposal Instructions to aid you in the completion of your Phase II proposal for Cycle 10. If you have specific questions not covered in the documents, you should consult your Program Coordinator, Contact Scientist (if one has been assigned), or send email to [email protected].
منابع مشابه
INSTITUTE Instrument Science Report STIS 2009 - 02 STIS CCD Performance after SM 4 : Read Noise , Dark Current , Hot Pixel Annealing , CTE , Gain , and Spectroscopic Sensitivity
We describe the overall performance of the STIS CCD after HST Servicing Mission #4 and the associated updates to calibration reference files. Most aspects of CCD performance are found to be fairly consistent with extrapolations of the trends seen prior to the failure of STIS in August 2004. The CCD gain value for the CCDGAIN = 4 setting has been redetermined using net count ratios of standard s...
متن کاملAn Algorithm for Correcting CTE Loss in Spectrophotometry of Point Sources with the STIS CCD
The correction for the change in sensitivity with time for the STIS CCD modes is complicated by the gradual loss of charge transfer efficiency (CTE) of the CCD. The amount of this CTE loss depends on time in orbit, the location on the CCD chip with respect to the readout amplifier, the stellar signal strength, and the background level. Primary constraints on our correction algorithm are provide...
متن کاملA new CTE Correction Algorithm for Point Source Spectroscopy with the STIS CCD : Correcting for charge trap filling by the ‘ red halo ’ of the CCD Point Spread Function redward of 8000 Å
The CTE-related loss for spectrophotometry of point sources with the STIS CCD is parametrized in terms of dependencies on the signal level of the source spectrum within the extraction box, the background level, and the signal in the point spread function located between the standard extraction box and the read-out amplifier. Primary constraints on the CTE correction algorithm are provided by es...
متن کاملSTIS Flux Calibration
The low dispersion STIS spectrophotometric flux calibration must account for all instrumental non-linearities and all changes in sensitivity with time and temperature. An empirical algorithm for CCD Charge Transfer Efficiency (CTE) is presented along with the wavelength dependent sensitivity changes. Precise STIS spectrophotometry includes corrections for CTE losses as large as 20% for faint si...
متن کاملThe Stis Ccd Cross-dispersion Point Spread Function
This report to outlines the work done by the Eta Carinae HST Treasury Project to determine the properties of the cross-dispersion point spread function for the HST Space Telescope Imaging Spectrograph (STIS) CCD. In this document we will refer to the cross-dispersion point spread function by the abbreviation: XSF. The goal of this work is to give a model for the STIS/CCD XSF which can be calcul...