Ventricular tachycardia initiated by high energy cardioversion in a patient with an implantable cardioverter defibrillator.
نویسندگان
چکیده
A transvenous implantable cardioverter defibrillator (ICD) was implanted into a 58 year old woman with idiopathic dilated cardiomyopathy who had drug refractory monomorphic ventricular tachycardia (VT). Antitachycardia pacing failed to terminate the VT; termination was attempted at 24 J, which was above the defibrillation threshold. When cardioversion at 24 J was delivered, VT with a different morphology and slower rate was reproducibly initiated. At 3 J, however, the original VT was successfully terminated without initiation of the slower VT. A new VT may be induced by high energy cardioversion. This may be a manifestation of the proarrhythmic potential of ICDs.
منابع مشابه
cardioverter defibrillator . cardioversion in a patient with an implantable Ventricular tachycardia initiated by high energy
Accepted for publication 9 December 1996 Abstract A transvenous implantable cardioverter defibrillator (ICD) was implanted into a 58 year old woman with idiopathic dilated cardiomyopathy who had drug refractory monomorphic ventricular tachycardia (VT). Antitachycardia pacing failed to terminate the VT; termination was attempted at 24 J, which was above the defibrillation threshold. When cardiov...
متن کاملImplantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملIntraoperative defibrillation threshold testing and postoperative long-term efficacy of cardioverter-defibrillator implantation
The aim of this study was to determine the defibrillation threshold (DFT) of implantable cardioverter-defibrillators (ICDs) and outcomes of treatment. Sixty-four patients received cardioverter-defibrillator implantation. During implantation, the DFT was determined by the defibrillation safety margin (DSM). All patients were followed up for 12-48 months after the implantation. The overall DFT wa...
متن کاملRisks and Benefits of Catheter Ablation of Ventricular Tachycardia in Patients with an Implantable Cardioverter-Defibrillator
Patients with an implantable cardioverterdefibrillator (ICD) may receive frequent shocks or antitachycardia pacing for monomorphic ventricular tachycardia despite suppressive drug therapy. Antitachycardia pacing is often well-tolerated but not always effective. High voltage cardioversion is usually painful and may cause severe, disabling anxiety for some patients. Therefore, catheter ablation i...
متن کاملTemporal Trends and Temperature-Related Incidence of Electrical Storm
Electrical storm (ES) is usually defined as the occurrence of ≥3 episodes of sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) within 24 hours requiring either antitachycardia pacing or cardioversion/defibrillation. ES represents a true medical emergency that requires a multidisciplinary approach, and its prevalence is steadily rising along with the number of patients bear...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Heart
دوره 77 4 شماره
صفحات -
تاریخ انتشار 1997