The new glucose standard POCT12-A3 misses the mark.

نویسنده

  • Jan S Krouwer
چکیده

POCT12-A3 is a Clinical Laboratory Standards Institute standard for hospitals about hospital glucose meter procedures and performance standards. I have reviewed this standard based on the attributes of an ideal performance standard. POCT12-A3 has tighter limits than its predecessor for 95% of results, the limits widen for 98% of results, and there are no limits for 2% of results. It is hard to fathom that 2% of the results are unspecified and could cause life-threatening results, as glucose meters do not perform this poorly. There should be a specification for unreported results since, by definition, point-of-care-testing assays are time sensitive. POCT12-A3 provides useful advice about the glucose testing procedure but provides evaluation guidance only about analytical performance. Moreover, the recommended protocol to assess meter performance is biased and likely to underestimate the observed performance. The guideline would be improved if its specification were based on an error grid and contained evaluation protocols for user errors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytic evaluation of a new glucose meter system in 15 different critical care settings.

BACKGROUND Maintaining appropriate glycemic control in critically ill patients reduces morbidity and mortality. The use of point-of-care (POC) glucose devices is necessary to obtain rapid results at the patient's bedside. However, the devices should be thoroughly tested in the intended population before implementation. The use of POC glucose meters in critically ill patients has been questioned...

متن کامل

Analysis: New point-of-care blood glucose monitoring system for the hospital demonstrates satisfactory analytical accuracy using blood from critically ill patients--an important step toward improved blood glucose control in the hospital.

Patients managed in the intensive care units (ICUs) and general wards of the hospital experience a high incidence of hyperglycemia, hypoglycemia, and glycemic variability, despite significant hospital resources devoted to glucose control. Optimized glucose meters and monitoring systems are required to improve the safety and efficacy of insulin delivery and glucose control in the hospital. Safe ...

متن کامل

Bedside Glucose Monitoring—Is it Safe? A New, Regulatory-Compliant Risk Assessment Evaluation Protocol in Critically Ill Patient Care Settings*

OBJECTIVES New data have emerged from ambulatory and acute care settings about adverse patient events, including death, attributable to erroneous blood glucose meter measurements and leading to questions over their use in critically ill patients. The U.S. Food and Drug Administration published new, more stringent guidelines for glucose meter manufacturers to evaluate the performance of blood gl...

متن کامل

Flow Cytometry: A New Approach for Indirect Assessment of Sperm Protamine Deficiency

Background Flow cytometry (FCM) has been extensively used to study mammalian sperm in the areas of clinical andrology and reproductive toxicology. FCM provides a powerful advantage over microscopy technique in terms of rapid accurate and reproducible technology for the quantification of various cell characteristics including chromatin status. During spermiogenesis histones are replaced by prota...

متن کامل

The role of adenosine A3 receptors in cytotoxicity of the breast cancer cell lines

The nucleoside adenosine is present within cells and body fluids of all living organisms and its production, both intra- and extracellularly, is tightly coupled to energy consumption resulting in increased level of extracellular adenosine. The physiological effects of adenosine are mediated through four pharmacologically and biochemically distinct adenosine receptors (AR), i.e. A1, A2A, A2B and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 7 5  شماره 

صفحات  -

تاریخ انتشار 2013