Thermo- and Photoacoustic Tomography with Variable Speed and Planar Detectors
نویسندگان
چکیده
We analyze the mathematical model of multiwave tomography with a variable speed with integrating measurements on planes tangent to a sphere surrounding the source. We prove sharp uniqueness and stability estimates with full and partial data and propose a time reversal algorithm which recovers the visible singularities.
منابع مشابه
Boundary conditions in photoacoustic tomography and image reconstruction.
Recently, the field of photoacoustic tomography has experienced considerable growth. Although several commercially available pure optical imaging modalities, including confocal microscopy, two-photon microscopy, and optical coherence tomography, have been highly successful, none of these technologies can penetrate beyond approximately 1 mm into scattering biological tissues because all of them ...
متن کاملPhotoacoustic tomography with a limited-aperture planar sensor and a reverberant cavity
Biomedical photoacoustic tomography (PAT) is a soft-tissue imaging modality which combines the high spatial resolution of ultrasound (US) with the contrast and spectroscopic opportunities afforded by imaging optical absorption. Planar US arrays composed of piezoelectric or optical detector elements with small element sizes and fast acquisition times are readily available, making them an attract...
متن کاملA new acoustic lens material for large area detectors in photoacoustic breast tomography☆
OBJECTIVES We introduce a new acoustic lens material for photoacoustic tomography (PAT) to improve lateral resolution while possessing excellent acoustic acoustic impedance matching with tissue to minimize lens induced image artifacts. BACKGROUND A large surface area detector due to its high sensitivity is preferable to detect weak signals in photoacoustic mammography. The lateral resolution ...
متن کاملTripling the detection view of high-frequency linear-array-based photoacoustic computed tomography by using two planar acoustic reflectors.
BACKGROUND Linear-array-based photoacoustic computed tomography (PACT) suffers from a limited view. Circular scanning does increase the detection view angle but is time-consuming. Therefore, it is desirable to increase the detection view angle of linear-array-based PACT without sacrificing imaging speed. METHODS Two planar acoustic reflectors placed at 120 degrees to each other were added to ...
متن کاملPerformance characterization of low-cost, high-speed, portable pulsed laser diode photoacoustic tomography (PLD-PAT) system.
Photoacoustic tomography systems that uses Q-switched Nd:YAG/OPO pulsed lasers are expensive, bulky, and hence limits its use in clinical applications. The low pulse repetition rate of these lasers makes it unsuitable for real-time imaging when used with single-element ultrasound detector. In this work, we present a pulsed laser diode photoacoustic tomography (PLD-PAT) system that integrates a ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- SIAM J. Math. Analysis
دوره 49 شماره
صفحات -
تاریخ انتشار 2017