[Pharmacokinetic and clinical effects of two bupivacaine concentrations on axillary brachial plexus block].
نویسندگان
چکیده
INTRODUCTION The risk of systemic bupivacaine toxicity is a persistent problem, which makes its pharmacokinetic study fundamental for regional anesthesia safety. There is little evidence of its influence on plasma peak at different concentrations. The present study compares two bupivacaine concentrations to establish how the concentration affects this drug plasma peak in axillary brachial plexus block. Postoperative latency and analgesia were also compared. METHODS 30 patients were randomized. In the 0.25% Group, 0.25% bupivacaine (10mL) was injected per nerve. In the 0.5% Group, 0.5% bupivacaine (5mL) was injected per nerve. Peripheral blood samples were collected during the first 2hours after the blockade. For sample analyses, high performance liquid chromatography mass spectrometry was used. RESULTS Plasma peak occurred 45minutes after the blockade, with no difference between groups at the assessed time-points. Plasma peak was 933.97 ± 328.03 ng.mL-1 (mean ± SD) in 0.25% Group and 1022.79 ± 253.81 ng.mL-1 in 0.5% Group (p = 0.414). Latency was lower in 0.5% Group than in 0.25% Group (10.67 ± 3.71 × 17.33min ± 5.30, respectively, p = 0.004). No patient had pain within the first 4hours after the blockade. CONCLUSION For axillary brachial plexus block, there was no difference in bupivacaine plasma peak despite the use of different concentrations with the same local anesthetic mass. The concentration inversely influenced latency.
منابع مشابه
Combined axillary block with "selective" injection of nerves and the axillary catheter: comparison of bupivacaine 0.25% or levobupivacaine 0.25%.
PURPOSE The aim of this study is to apply combination of axillary plexus block with "selective" injection of nerves and continuous catheter technique, and to compare the anesthetic and postoperative analgesic effects of bupivacaine and levobupivacaine. METHODS In 30 scheduled patients for unilateral hand or forearm surgery, an axillary brachial plexus block with "selective" injection of nerve...
متن کاملClinical and radiological comparison of perivascular and transarterial techniques of axillary brachial plexus block.
The perivascular technique of axillary brachial plexus block results in incomplete block of radial and musculocutaneous nerves in 10-20% of patients. With the transarterial technique and a large dose of mepivacaine, success rates of 99% have been reported. We have compared the clinical efficacy of these techniques in 50 patients using 1% mepivacaine 45 ml with adrenaline. If required, the block...
متن کاملEvaluation of the analgesic effect of 2 doses of verapamil with bupivacaine compared with bupivacaine alone in supraclavicular brachial plexus block
Abstract Background: Different adjuvant drugs have been used with local anesthetics in order to decrease the time of onset and elongate the duration and quality of regional blocks. This study was performed to study the effects of one of the adjuvants, verapamil, in supraclavicular block. Methods: In this double blinded clinical trial, we divided 60 ASA class I and II patients who were to under...
متن کاملConvulsion due to levobupivacaine in axillary brachial plexus block: Case report
Axillary brachial plexus block is an effective method of anaesthesia for the surgeries performed on the hand, forearm and distal third of the arm. However it has the risk of serious complications such as cardiovascular and central nervous system toxicity. Levobupivacaine is a long acting amide local anaesthetic used for epidural, caudal, spinal, infiltration and peripheral nerve blocks. Levobup...
متن کاملRegional anesthesia for upper extremity surgery--our experience.
Brachial plexus block using axillary approach is a simple and safe method of regional anesthesia often used for elbow, forearm and hand surgery. Different techniques can be used to achieve brachial plexus block. On using perivascular approach to brachial plexus, we neither searched for paresthesia nor used nerve stimulator to identify the correct needle position within the neurovascular sheet. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista brasileira de anestesiologia
دوره 68 2 شماره
صفحات -
تاریخ انتشار 2018