DCIV and Spectral Charge-Pumping Studies of -Ray and X-ray Irradiated Power VDMOSFET Devices

نویسنده

  • M.-S. Park
چکیده

This paper reports the total dose effects and post-irradiation anneal effects on the two recombination current peaks and the bottom current in commercial power VDMOSFET devices irradiated with Cs -ray or X-ray radiation. The two interface recombination current peaks show a slightly different rate of increase as a function of the radiation dose. Slightly different diode ideality factors are found in an n-channel device, 1.70 0.10, 1.60 0.10 and 1.20 0.10 for the two DCIV current peaks and the bottom current, respectively. The saturation current of the gated diode, i.e., VDMOSFET, normalized by the input capacitance is shown to be a good parameter to monitor the interface state density. Spectral charge pumping data show that, of the above-midgap interface traps in an n-channel device, the energy below about + 0 18 eV has a most significant increase in radiation-induced trap density and these traps may be responsible for the DCIV current peaks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Radiation Effects in -Ray Irradiated Power VDMOSFET by DCIV Technique

Direct-current current–voltage (DCIV) measurement was used to monitor interface recombination currents in 137 -ray irradiated commercial power VDMOSFETs. The data are correlated with the subthreshold I–V data and charge-pumping current data, which are obtained after various biased-annealing steps. The DCIV method is found to be a convenient technique in monitoring the radiation effects in power...

متن کامل

X-ray Charge-Dens Study of 5-Chloro-8-hydroxy-6-methyloaphthalene-l.4-dione: A Hydroxynaphthoquinone Derivative

The X-ray charge density analysis of a hydroxynaphthoquinnne derivative was obtained by multipolar Hansen-Coppens formalism refinement through high resolution X-ray diffraction data at 100(1) K. The molecularproperties of the title compound resulted from the combined experimental and the quantum theory of atoms inmolecules (QTAIM) studies. The topological properties of the covalent bonds and of...

متن کامل

Determination of hemolysis, osmotic fragility and fluorescence anisotropy on irradiated red blood cells as a function of kV of medical diagnostic X-rays

Background: People occasionally undergo medical diagnostic X-ray examinations and expose their red blood cells to radiation. Radiation that is generated from medical diagnostic X-ray machines is widely used in medical diagnoses. One of the important parameters is kilo-voltage (kV) that is applied across the X-ray tube in medical diagnostic X-ray machines. Kilo-voltage influences the radiation d...

متن کامل

Rare Earth Nitrate Complexes with an ONO Schiff Base Ligand: Spectral, Thermal, Luminescence and Biological Studies

Five rare earth complexeslanthanum(III),praseodymium(III),neodymium(III), samarium(III) and europium(III) have been synthesized from Schiff base ligand (N,N-bis (2-hydroxy-1-naphthylidene) acetylhydrazone). The complexes were characterized based on elemental analysis, molar conductance, ultraviolet, infrared, mass, thermogravimetric and powder X-ray diffraction studies. Infrared spectra sug...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010