Computational fluid dynamics applied to virtually deployed drug-eluting coronary bioresorbable scaffolds: Clinical translations derived from a proof-of-concept

نویسندگان

  • Bill D. Gogas
  • Boyi Yang
  • Tiziano Passerini
  • Alessandro Veneziani
  • Marina Piccinelli
  • Gaetano Esposito
  • Emad Rasoul-Arzrumly
  • Mosaab Awad
  • Girum Mekonnen
  • Olivia Y. Hung
  • Beth Holloway
  • Michael McDaniel
  • Don Giddens
  • Spencer B. King
  • Habib Samady
چکیده

BACKGROUND Three-dimensional design simulations of coronary metallic stents utilizing mathematical and computational algorithms have emerged as important tools for understanding biomechanical stent properties, predicting the interaction of the implanted platform with the adjacent tissue, and informing stent design enhancements. Herein, we demonstrate the hemodynamic implications following virtual implantation of bioresorbable scaffolds using finite element methods and advanced computational fluid dynamics (CFD) simulations to visualize the device-flow interaction immediately after implantation and following scaffold resorption over time. METHODS AND RESULTS CFD simulations with time averaged wall shear stress (WSS) quantification following virtual bioresorbable scaffold deployment in idealized straight and curved geometries were performed. WSS was calculated at the inflow, endoluminal surface (top surface of the strut), and outflow of each strut surface post-procedure (stage I) and at a time point when 33% of scaffold resorption has occurred (stage II). The average WSS at stage I over the inflow and outflow surfaces was 3.2 and 3.1 dynes/cm(2) respectively and 87.5 dynes/cm(2) over endoluminal strut surface in the straight vessel. From stage I to stage II, WSS increased by 100% and 142% over the inflow and outflow surfaces, respectively, and decreased by 27% over the endoluminal strut surface. In a curved vessel, WSS change became more evident in the inner curvature with an increase of 63% over the inflow and 66% over the outflow strut surfaces. Similar analysis at the proximal and distal edges demonstrated a large increase of 486% at the lateral outflow surface of the proximal scaffold edge. CONCLUSIONS The implementation of CFD simulations over virtually deployed bioresorbable scaffolds demonstrates the transient nature of device/flow interactions as the bioresorption process progresses over time. Such hemodynamic device modeling is expected to guide future bioresorbable scaffold design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel approach to treat in-stent restenosis: 6- and 12-month results using the everolimus-eluting bioresorbable vascular scaffold.

AIMS The treatment of in-stent restenosis (ISR) remains challenging. Small case series have described successful utilisation of bioresorbable vascular scaffolds (BVS) (Absorb; Abbott Vascular, Santa Clara, CA, USA) to treat ISR. We report our experience with this novel approach. METHODS AND RESULTS Patients with ISR in native coronary arteries undergoing percutaneous coronary intervention (PC...

متن کامل

Bioresorbable Scaffold: The Emerging Reality and Future Directions.

In the era of drug-eluting stents, large-scale randomized trials and all-comer registries have shown excellent clinical results. However, even the latest-generation drug-eluting stent has not managed to address all the limitations of permanent metallic coronary stents, such as the risks of target lesion revascularization, neoatherosclerosis, preclusion of late lumen enlargement, and the lack of...

متن کامل

Bioresorbable Vascular Scaffolds for Coronary Revascularization.

Contemporary metallic drug-eluting stents are associated with very good 1-year outcomes but an ongoing risk of stent-related adverse events (thrombosis, myocardial infarction, restenosis) after 1 year. The pathogenesis of these very late events is likely related to the permanent presence of the metal stent frame or polymer. Bioresorbable scaffolds have been developed to provide drug delivery an...

متن کامل

Coronary Bioresorbable Vascular Scaffold Use in the Treatment of Coronary Artery Disease.

Bioresorbable vascular scaffolds (BVS) represent a promising novel approach for the treatment of coronary artery disease. BVS promise to address some of the well-known limitations of current drug-eluting stents, while providing a transient scaffolding of the vessel to prevent acute vessel closure/recoil. Drug elution by BVS prevents neointimal proliferation in a similar fashion to drug-eluting ...

متن کامل

Current status of bioresorbable scaffolds in the treatment of coronary artery disease.

State-of-the-art drug-eluting metal stents are the gold standard for interventional treatment of coronary artery disease. Although they overcome some disadvantages and limitations of plain balloon angioplasty and bare-metal stents, some limitations apply, most notably a chronic local inflammatory reaction due to permanent implantation of a foreign body, restriction of vascular vasomotion due to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014