Detecting differences in volume pulse wave parameters among fingers and toes in four different postures.

نویسندگان

  • Tingting Yan
  • Lin Yang
  • Song Zhang
  • Yimin Yang
  • Xuwen Li
چکیده

The measurement of volume pulse waves may be easily affected based on the measured position (different fingers or toes), body posture, as well as other factors. Therefore, interferences during measurement need to be removed. For this study, relevant parameters of volume pulse wave were obtained by changing the affecting factors. The data were analyzed in order to indicate the differences in volume pulse wave parameters among different fingers and toes in four postures. Results showed that when subjects were lying, inclined or in a sitting posture, volume pulse wave parameters of the index finger, middle finger and ring finger on both hands displayed no apparent differences. When subjects were in a sitting posture, volume pulse wave parameters of the big, second and third toes on both feet showed no significant differences.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of blood volume pulse and skin conductance responses to mental and affective stimuli at different anatomical sites.

Measurements of blood volume pulse (BVP) and skin conductance are commonly used as indications of psychological arousal in affective computing and human-machine interfaces. To date, palmar surfaces remain the primary site for these measurements. Placement of sensors on palmar surfaces, however, is undesirable when recordings are fraught with motion and pressure artifacts. These artifacts are fr...

متن کامل

Raynaud's phenomenon of fingers and toes among vibration-exposed patients.

Eleven patients with Raynaud's phenomenon of the toes as well as the fingers were encountered among about 1,000 vibration-exposed patients. They consisted composed of four chain-saw operators, five rock drillers, a stone quarrier and a welder in a shipyard. All the cases were examined carefully for differential diagnosis, but there were no particular abnormalities in hematological, immunologica...

متن کامل

Effect of Digital Block on Pulse Oximeter Signal Detection during General Anesthesia

Pulse oximetry is dependent upon the presence of a pulsating vascular bed. Low pulsatile blood flow in the digits is caused by various factors. Regardless of the cause, if there is sufficient arterial pulse pressure, blocking the sympathetic nerve should cause a local increase in capillary flow and pulse volume. This study was performed to evaluate the effect of digital nerve block on pulse oxi...

متن کامل

Second Derivative Photoplethysmography Implementation

Photoplethysmography (PPG) provides an estimation of blood flow by measuring the dynamic attenuation of visual or infrared light by the blood volume present in tissue. The contour of the pulsatile component of the PPG signal has been found to include content descriptive of vascular health. PPG pulse signals can be easily obtained from the tissue pads of the ears, fingers and toes where there is...

متن کامل

Correlation between Mean Serum Ferritin Levels and Atrial Electrocardiographic Markers in Beta-Thalassemia Major

Background: Atrial fibrillation (AF) is the most common arrhythmia in patients with β-thalassemia major (β-TM) due to cardiac iron overload. AF may be predicted by changes in P wave parameters. The aim of this study was to evaluate the correlation between P-wave parameters and atrial markers with mean serum ferritin levels measured yearly. Methods: Fifty patients with β-TM and 50 healthy subje...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bio-medical materials and engineering

دوره 26 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2015