چکیده
A catalytic polarographic method for the determination of microgram quantities of Ce(IV) is developed based on the catalytic currents of cerium(IV) in the presence of NH4Cl – NH4OH at pH 6.2 with piperazine. Piperazine produces catalytic current with Ce(IV) at peak potential -0.1 to -0.6 V vs. SCE. The procedure was applied for the estimation of Ce(IV) in water samples. The method is simple, sensitive and free from interference of many metal ions.
منابع مشابه
A NOVEL AND HIGHLY SENSITIVE CATALYTIC METHOD FOR THE DETERMINATION OF ULTRA TRACE AMOUNTS OF CERIUM WITH SPECTROPHOTOMETRIC DETECTION
Cerium (IV) has a catalytic effect on the very slow redox reaction between gallocyanine and bromate in acidic media. The reaction was monitored spectrophotometrically at 525 nm by a fixed time method of 4.0 rnin from initiation of the reaction. The decrease in absorbance at 525 nm is proportional to the Ce (IV) concentration in the range of 0.005-1.000 and 1.00-10.00 pg. ml-l. The limit of ...
متن کاملSensitive Kinetic Spectrophotometric method for Trace determination of Cerium (IV) Based on decolarization of Nile blue by potassium Periodate
A simple and sensitive kinetic spectrophotometric method for the determination of trace amounts of cerium (IV), based on the catalytic effect of Ce (IV) on the oxidation of Nile blue (NB) by potassium periodate is described. The reaction rate was monitored spectrophotometrically by measuring the decrease in absorbance of NB at 636 nm. The detection limit of the method was 0.15 g ml and the line...
متن کاملTrace Amounts Determination of Vanadium (V) Using a New Kinetic-Catalytic Reaction System
This study describes a new simple, sensitive and selective catalytic kinetic spectrophotometricmethod for the determination of vanadium (V). The method is based upon the catalytic effect ofvanadium (V) on the oxidation of Carminic acid by bromate in sulfuric acid media. The reaction wasfollowed spectrophotometrically by measuring the decrease in absorbance at 490 nm and thedependence of sensiti...
متن کاملA Facile Catalytic- Kinetic Method for The Determination of Selenium (IV)
A catalytic-kinetic method for the determination of selenium is proposed. Alizarin navy blue is reduced by sodium sulfide to from a colorless product. The reaction is accelerated by trace amounts of Se (IV), and can be followed by measuring the decrease in absorbance of the dye at 620nm and 30 °C by the fixed time method. Selenium can be determined in the range of 0.004 — 0.12 1.1g.m1-1 . ...
متن کاملJanus Green Dye as a New Reagent for Catalytic Kinetic Determination of Zirconium in Ceramic Materials
A new catalytic kinetic spectrophotometric procedure for determination of trace quantities of zirconium was proposed. Janus Green was oxidized by potassium bromate and zirconium catalyst which then converted to a colorless product in acidic media. Reaction rate was monitored spectrophotometrically at 606 nm. It relies on the linear relationship between the absorbance difference (ΔAt) and Zr(IV)...