Increase in IUD expulsions.

نویسنده

  • Rajendra Prasad Yadava
چکیده

failed. Many colleagues have tried this method and they have had success with it also. I had correspondence from the French company that unless the article were to be endorsed by a professor or senior consultant/colleague in family planning then they were not prepared to change the design. The Ortho Gynae T 380® was discontinued, however it has been adopted for use by other manufacturers with only minor changes, and I am afraid the inherent problem is still present. One has tried to make loading easier but still the problem doesn’t disappear completely. My proposal was very simple: no matter how you load the introducer rod in the tube it should come out outside the top opening and then one can be absolutely sure that the IUD is released totally and completely and that there is no chance of the IUD being pulled down. For those colleagues who would like to try my technique they should do the following. Put the IUD on sterile paper. Pull the IUD out further up so that one does not cut the thread. Line the rod against the tube with the rod just a few millimetres (say 4–5 mm) higher than the opening and then the lower end of the tube should be cut, which should rest at the end of the rod where there is a ring. Subsequent fitting should now be easier.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Partial and complete expulsion of the Multiload 375 IUD and the levonorgestrel-releasing IUD after correct insertion.

OBJECTIVE The contraceptive efficacy of intrauterine devices (IUD) is thought to relate to the position of the IUD in the uterine cavity. Several trials examined the number of copper IUD expulsions, but none evaluated the partial and complete expulsion rate of the levonorgestrel-releasing device (LNG-IUD). STUDY DESIGN This retrospective cohort study compares the dislocation rate of the Multi...

متن کامل

Spontaneous Lippes Loop IUCD Intravesical Migration with Formation of Bladder Calculus and Vesicovaginal Fistula: A Case Report

Submit Manuscript | http://medcraveonline.com Spontaneous expulsions are rare, but can occur in the first months of usage, especially when the IUD is inserted shortly after childbirth. Uterine perforation is an extremely rare complication with a rate of 0.4/1000 insertions [1]. Perforation can occur during the insertion of IUD so it is recommended to be performed by an experienced gynaecologist...

متن کامل

Timing of copper intrauterine device insertion after medical abortion: a randomized controlled trial.

OBJECTIVE To compare intrauterine device (IUD) use at 6 months in women randomized to receive an intrauterine copper contraceptive 1 week compared with 1 month after medical abortion. METHODS We recruited women undergoing medical abortion with mifepristone and misoprostol and choosing the copper IUD for contraception. We randomly assigned participants to "immediate" insertion 1 week after mif...

متن کامل

Use of frameless intrauterine devices and systems in young nulliparous and adolescent women: results of a multicenter study

BACKGROUND The purpose of this study was to provide additional data on the experience with frameless copper and levonorgestrel (LNG) intrauterine devices (IUDs) in nulliparous and adolescent women. METHODS Nulliparous and adolescent women, 25 years of age or younger, using the frameless copper IUD or the frameless LNG-releasing intrauterine system (IUS), were selected from previous studies an...

متن کامل

The challenge to solve the expulsion problem of immediate postplacental insertion of IUD.

We have read with interest the article by Cohen et al. entitled “Twelve-month contraceptive continuation and repeat pregnancy among young mothers choosing post-delivery contraceptive implants or postplacental intrauterine devices” [1]. What strikes us time and time again in articles published on postplacental/postpartum insertion of IUDs is the unacceptable high total expulsion as well as the h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of family planning and reproductive health care

دوره 33 2  شماره 

صفحات  -

تاریخ انتشار 2007