Pinnacle revision cup in acetabular surgery results at 2 to 5 years.
نویسندگان
چکیده
Uncemented revision cups are widely used in revision hip arthroplasty; they have shown good results. We report the the short term outcome with the cementless Pinnacle revision cup. All acetabular revisions using a Pinnacle revision cup between January 2007 and March 2010 were included. In March 2012, clinical scores were determined and the latest radiographs were assessed. Revision and radiographic signs of loosening were reported as failure of the cup. Ths study included 117 patients (118 revision cups) with a follow-up between two and five years. Five cups failed (4%). The median modified Harris Hip Score was 64 (range : 18-91). Survival rates of the Pinnacle revision cup are good in the short term follow-up. This implant appears as a safe and reliable solution for small to moderate acetabular defects.
منابع مشابه
Isolated polyethylene exchange versus acetabular revision for polyethylene wear.
UNLABELLED Polyethylene wear and osteolysis are not uncommon in THA mid- and long-term. In asymptomatic patients the dilemma faced by the orthopaedic surgeon is whether to revise the cup and risk damage to the supporting columns and even pelvic discontinuity or to perform isolated polyethylene exchange and risk a high rate of postoperative recurrent instability and dislocation that will necessi...
متن کاملAcetabular revision with impacted morsellised cancellous bone grafting and a cemented cup. A 15- to 20-year follow-up.
This study presents the clinical and radiological results of 62 consecutive acetabular revisions in 58 patients, at a mean of 16.5 years follow-up (15 to 20). The Kaplan-Meier survivorship for the cup with end-point revisions for any reason, was 79% at 15 years (95% confidence interval (CI); 67 to 91). Excluding two revisions for septic loosening at three and six years, and one revision of a we...
متن کاملLate liner disassociation of a Pinnacle system acetabular component.
This article describes a case of late locking mechanism failure and disassociation of a Pinnacle acetabular cup (DePuy, Warsaw, Indiana) and Marathon polyethylene liner (DePuy) 53 months after routine primary total hip arthroplasty in an active patient. Following an uncomplicated initial postoperative recovery, the patient felt a pop while kneeling for gardening activities. The patient had no p...
متن کاملAcetabular revision in total hip replacement with a press-fit cup.
The need for supplementary screw fixation in acetabular revisions is still widely debated. We carried out 439 acetabular revisions over an eight-year period. In 171 hips with contained or small segmental defects, the Morscher press-fit cup was used. These revisions were followed prospectively. No screws were used for additional fixation. A total of 123 hips with a mean follow-up of 7.4 years (5...
متن کاملShort-term survival of the trabecular metal cup is similar to that of standard cups used in acetabular revision surgery
BACKGROUND AND PURPOSE The use of trabecular metal (TM) cups in revision surgery has increased worldwide during the last decade. Since the introduction of the TM cup in Sweden in 2006, this design has gradually replaced other uncemented designs used in Sweden. According to data from the Swedish Hip Arthroplasty Register (SHAR) in 2012, one-third of all uncemented first-time cup revisions were p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 79 4 شماره
صفحات -
تاریخ انتشار 2013