High frequency jet ventilation and gas trapping.
نویسندگان
چکیده
We have compared three types of high frequency jet ventilation (HFJV) with conventional positive pressure ventilation in patients recovering from elective coronary artery bypass surgery. Twelve patients were allocated randomly to receive HFJV at ventilatory frequencies of 60, 100, 150 and 200 bpm from a standard jet ventilator at either the proximal or distal airway (HFJV.p and HFJV.d), or from a valveless high frequency jet ventilator acting as a pneumatic piston (VPP). Trapped gas volume (Vtr), cardiac index (CI) and right ventricular ejection fraction (RVEF) were measured. Vtr was related to the type of HFJV used (P < 0.05) and ventilatory frequency (P < 0.05). CI decreased with increasing rate of HFJV (P < 0.05) and there were significant differences between the three types of HFJV (P < 0.05). RVEF showed a linear relationship with ventilatory frequency (P < 0.05) decreasing most with the VPP. The decrease in RVEF was associated with an increase in right ventricular end-systolic volume (P < 0.05) suggesting that an increase in right ventricular afterload was the cause. The same three types of HFJV were compared using a lung model with variable values of compliance and resistance, to assess the impact of lung mechanics on gas trapping (Vtr, ml). Lung model compliance (C) was set at 50 or 25 ml cm H2O-1 and resistance (R) at 5 or 20 cm H2O litre-1 s, where values of 50 and 5, respectively, are normal. Vtr increased with ventilatory frequency for all types of jet ventilation (P < 0.05), varying with the type of jet ventilation used (P < 0.05).
منابع مشابه
Heliox administration during high-frequency jet ventilation augments carbon dioxide clearance.
We report the combined use of heliox and high-frequency jet ventilation to augment carbon dioxide clearance, with a focus on the important technical considerations. Our case is a 5-month old infant with acute respiratory failure associated with gas trapping, hypercarbia, respiratory acidosis, and air leak. Despite maximal conventional ventilation, bronchodilator therapy, corticosteroids, and se...
متن کاملRESPIRATION AND THE AIRWAY Frequency dependence of lung volume changes during superimposed high-frequency jet ventilation and high-frequency jet ventilation
Editor’s key points † Superimposed high-frequency jet ventilation (SHFJV) involves simultaneous normal frequency (12–20 min) and high-frequency jet ventilation (HFJV) (.500 min). † SHFJV may improve ventilation and gas exchange compared with HFJValone, but the optimum frequencies for SHFJV are unknown. † In this animal model, end-expiratory and tidal volumes determined by opto-electronic plethy...
متن کاملTracheal gas insufflation and related techniques to introduce gas flow into the trachea.
Over the past 50 years, a variety of techniques have been developed that have in common the insufflation of gas into the central airway to facilitate carbon dioxide (CO2) clearance. These include continuous insufflation of oxygen, transtracheal jet ventilation, high frequency jet ventilation, transtracheal oxygen administration, intratracheal pulmonary ventilation, and tracheal gas insufflation...
متن کاملAprospective randomized study comparing respiratory efficacy of percutaneous transtracheal and endotracheal, low-frequency jet ventilation during microlaryngeal surgery
Abstract Background: Transtracheal jet ventilation is an alternative ventilatory approach in airway surgery. The purpose of this study was to compare respiratory efficacy of percutaneous transtracheal with endotracheal, low frequency jet ventilation during microlaryngeal surgery. Methods: Ninety ASA class I-II patients aged between 16 and 70 years undergoing elective microlaryngeal surgery wer...
متن کاملRelationship between resonance and gas exchange during high frequency jet ventilation.
We have studied the relationship between gas exchange and mechanical frequency response during high frequency jet ventilation (HFJV) at 0.5-5.0 Hz in anaesthetized pigs. The mechanical gain curve showed a minimal "anti-resonant" response at 0.8 Hz (f1) and a maximal "resonant" response at 5.0 Hz (f2). This finding may be explained by modelling the thorax and abdomen as a system of coupled masse...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 83 5 شماره
صفحات -
تاریخ انتشار 1999