Determining photon energy absorption parameters for different soil samples
نویسندگان
چکیده
The mass attenuation coefficients (μs) for five different soil samples were measured at 661.6, 1173.2 and 1332.5 keV photon energies. The soil samples were separately irradiated with (137)Cs and (60)Co (370 kBq) radioactive point gamma sources. The measurements were made by performing transmission experiments with a 2″ × 2″ NaI(Tl) scintillation detector, which had an energy resolution of 7% at 0.662 MeV for the gamma-rays from the decay of (137)Cs. The effective atomic numbers (Zeff) and the effective electron densities (Neff) were determined experimentally and theoretically using the obtained μs values for the soil samples. Furthermore, the Zeff and Neff values of the soil samples were computed for the total photon interaction cross-sections using theoretical data over a wide energy region ranging from 1 keV to 15 MeV. The experimental values of the soils were found to be in good agreement with the theoretical values. Sandy loam and sandy clay loam soils demonstrated poor photon energy absorption characteristics. However, clay loam and clay soils had good photon energy absorption characteristics.
منابع مشابه
Investigations of parameters affecting the photon energy spectra of an 18 MV Varian 2100C/D linear accelerator
Radiotherapy using linear accelerators is known as an effective modality for cancer treatment. The photons energy of treatment beams significantly affect the dose distribution. Therefore, it is important to accurately evaluate the photon energy spectra. In this study, MCNPX Monte Carlo code (version 2.6.0) was used to simulate an 18 MV photon beam of a Varian 2100C/D linear accelerator. By matc...
متن کاملAn in-vivo study on the energy dependence of X-ray biological effectiveness
Background: The International Commission on Radiological Protection (ICRP) has attributed the same relative risk for X and gamma radiations of all energies. Several studies have proven that the biological effect of low energy photon is more than that of higher ones. The assessment of risks is important due to the wide use of low energy X-rays for mammography screening and other diagnostic appli...
متن کاملRadiation Absorption Characteristics of Titanium Alloys
Titanium alloys have found numerous applications in space research, and nuclear industry and research. Since X-rays constitute an important part of the space radiation environment, numerical simulations of radiation absorption characteristics of titanium alloys were studied in this paper. The photon transport Monte Carlo software was used for determining the energy deposited in titanium samples...
متن کاملPhoton dosimetry based on selective data sampling for the NaI(TL) detector
Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is tr...
متن کاملEffects of particle size and weight percentage of heavy metal elements on photon shielding efficiency of reinforced polymer composites
Background: Polymer composites when reinforced with heavy metals in the form of micro/nano particles are efficient gamma- and X-ray shielding materials providing such advantageous features as cost-effectiveness, light-weight factor, flexibility, non-toxicity, conformability over conventional shields. Materials and Methods: In this paper the influence of weight percentages and particle sizes of ...
متن کامل