X-ray fluorescence imaging of the hippocampal formation after manganese exposure.
نویسندگان
چکیده
Manganese (Mn) intoxication results in neurological conditions similar, but not identical, to idiopathic Parkinson's disease. While the mechanism(s) by which Mn exposure leads to neurotoxic effects remains unclear, studies by magnetic resonance imaging demonstrate a high Mn accumulation in the hippocampal formation (HPCf) of the brain. Metal quantification using this method is not possible. Using X-ray fluorescence imaging, we measured the distribution of Mn in the HPCf for a rodent model of chronic Mn exposure and quantitatively compared it with distributions of other biologically relevant metals. We found considerable increases in average Mn concentrations in all analyzed areas and we identified the dentate gyrus (DG) and the cornus ammonis 3 (CA3) layer as areas accumulating the highest Mn content (∼1.2 μg Mn per g tissue). The DG is significantly enriched with iron (Fe), while the CA3 layer has high zinc (Zn) content. Additionally, significant spatial correlations were found for Mn-Zn concentrations across the HPCf substructures and for Mn-Fe concentrations in the DG. Combined results support that at least two mechanisms may be responsible for Mn transport and/or storage in the brain, associated with either Fe or Zn. Subcellular resolution images of metal distribution in cells of the CA3 show diffuse Mn distributions consistent with Mn localization in both the cytoplasm and nucleus. Mn was not increased in localized intracellular Fe or copper accumulations. A consistent Mn-Zn correlation both at the tissue (40 μm × 40 μm) and cellular (0.3 μm × 0.3 μm) levels suggests that a Zn transport/storage mechanism in the HPCf is likely associated with Mn accumulation.
منابع مشابه
Retrospective assessment of radiation dose by Fluorescence In Situ Hybridization and evaluation of stable chromosomal aberrations
Estimation of absorbed dose for radiation workers or person involved in different radiological accident is the aim of biodosimetry. Cytogenetic methods are the most current and applicable biodosimetry tools. In chronic or protracted exposure, fluorescence in situ hybridization (FISH), stable chromosomal aberration is used for estimation of absorbed dose. For precise estimation of absorbed dose,...
متن کاملDissolution Kinetic Evaluation of Manganese-rich Iron ore by Sulphuric acid Solution
This study investigated the optimum conditions for the leaching of manganese-rich iron ore for subsequent beneficiation studies in laboratory scale. The experiments were carried out by varying the concentration of H2 SO4 solution and the leaching temperature. The properties of the iron ore was characterized by X-ray fluorescence (XRF), X-ray diffraction (XRD), Scanning Electron Microscopy (SEM)...
متن کاملManganese enhanced MRI in rat hippocampus: A correlative study with synchrotron X-ray microprobe
Manganese enhanced MRI (MEMRI) offers many possibilities such as tract tracing and functional imaging in vivo. Mn is however neurotoxic and may induce symptoms similar to those associated with Parkinson's disease (manganism). The mechanisms of Mn-induced neurotoxicity are not clear. In this study, we combine synchrotron X-ray fluorescence microprobe (SR-XRF) and MEMRI techniques to investigate ...
متن کاملEvaluation of hippocampal degeneration after prenatal radiation exposure using Manganese-enhanced MRI (MEMRI)
S. Saito, X-Z. Sun, K. Sawada, T. Suhara, I. Kanno, and I. Aoki Department of Molecular and Neuroimaging, Graduate School of Medicine, Tohoku University, Sendai, Miyagi, Japan, Regulation Science Research Group, National Institute of Radiological Sciences, Chiba, Japan, Laboratory of Anatomy, Department of Physical Therapy, Faculty of Medical and Health Sciences, Japan, Molecular Imaging Center...
متن کاملQuality assessment of conventional X-ray diagnostic equipment by measuring X-ray exposure and tube output parameters in Great Khorasan Province, Iran
Introduction: Regular implementation of quality control (QC) program in diagnostic X-ray facilities may affect both image quality and patient radiation dose due to the changes in exposure parameters. Therefore, this study aimed to investigate the status of randomly selected conventional radiographic X-ray devices installed in radiology centers of Great Khorasan Province, Iran, to produce the da...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Metallomics : integrated biometal science
دوره 5 11 شماره
صفحات -
تاریخ انتشار 2013