Distribution of power output during the cycling stage of a Triathlon World Cup.

نویسندگان

  • Thierry Bernard
  • Christophe Hausswirth
  • Yann Le Meur
  • Frank Bignet
  • Sylvain Dorel
  • Jeanick Brisswalter
چکیده

PURPOSE The aim of this study was to evaluate the power output (PO) during the cycle phase of the Beijing World Cup test event of the Olympic triathlon in China 2008. METHODS Ten elite triathletes (5 females, 5 males) performed two laboratory tests: an incremental cycling test during which PO, HR at ventilatory thresholds (VT1 and VT2), and maximal aerobic power (MAP) were assessed, and a brief all-out test to determine maximal anaerobic power output (MAnP). During the cycle part of competition, PO and HR were measured directly with portable device. The amount of time spent below PO at VT1 (zone 1), between PO at VT1 and VT2 (zone 2), between PO at VT2 and MAP (zone 3) and above MAP (zone 4) was analyzed. RESULTS A significant decrease in PO, speed, and HR values was observed during the race. The distribution of time was 51 +/- 9% for zone 1, 17 +/- 6% for zone 2, 15 +/- 3% for zone 3, and 17 +/- 6% was performed at workloads higher than MAP (zone 4). From HR values, the triathletes spent 27 +/- 12% in zone 1, 26 +/- 8% in zone 2, and 48 +/- 14% above VT2. CONCLUSIONS This study indicates a progressive reduction in speed, PO, and HR, coupled with an increase in variability during the event. The Olympic distance triathlon requires a higher aerobic and anaerobic involvement than constant-workload cycling exercises classically analyzed in laboratory settings (i.e., time trial) or Ironman triathlons. Furthermore, monitoring direct PO could be more suitable to quantify the intensity of a race with pacing strategies than classic HR measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cycling attributes that enhance running performance after the cycle section in triathlon.

PURPOSE To determine how cycling with a variable (triathlon-specific) power distribution affects subsequent running performance and quantify relationships between an individual cycling power profile and running ability after cycling. METHODS Twelve well-trained male triathletes (VO2peak 4.9 ± 0.5 L/min; mass 73.5 ± 7.7 kg; mean ± SD) undertook a cycle VO2peak and maximal aerobic power (MAP) t...

متن کامل

Biomechanical Analysis of the 10km-run in a Triathlon World Cup Event: Differences Presented by Women Gold Medal

In most of the triathlon races, the 10km-run is critical to win and, just a few seconds, may separate the gold and the silver medal. To our best knowledge, no study has analyzed the biomechanical differences among the first qualified triathletes during a top-level competition. The aims of the present study were: (1) to examine the different responses to the previous cycling between the gold med...

متن کامل

Swim Positioning and its Influence on Triathlon Outcome

Questions have been raised regarding which of the three legs of a triathlon influences the final finishing position. Some coaches subjectively believe that the swim and run are more important than the cycle, especially since the introduction of drafting during the cycle. This study analysed race position shifts between each of the three disciplines to assess the importance of the swim finish po...

متن کامل

Differences in gender and performance in off-road triathlon.

The aims of this study were: (1) to examine performance trends and compare elite male and female athletes at the off-road triathlon (1.5-km swim, 30-km mountain biking, and 11-km trail running) world championships since its inception in 1996, and (2) to compare gender-related differences between off-road triathlon and conventional road-based triathlon. Linear regression analyses and ANOVA were ...

متن کامل

Robust Control of Power System Stabilizer Using World Cup Optimization Algorithm

In this paper, we propose a new optimized PID controller to stabilize the synchronous machine connected to an infinite bus. The model for the synchronous machine is 4-ordered linear Philips-Heffron synchronous machine. In this research, the parameters of the PID controller are optimally achieved by minimizing a definite fitness function to removes the unstable Eigen-value to the left side of im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medicine and science in sports and exercise

دوره 41 6  شماره 

صفحات  -

تاریخ انتشار 2009