Identification of surgically-induced longitudinal lesions of the equine deep digital flexor tendon in the digital flexor tendon sheath using contrast-enhanced ultrasonography: an ex-vivo pilot study
نویسندگان
چکیده
BACKGROUND Longitudinal tears in the lateral aspect of the deep digital flexor tendon are the most common causes of pain localised to the equine digital flexor tendon sheath. However conventional ultrasonographic techniques provide limited information about acute lesions. Ultrasonographic contrast agents are newly developed materials that have contributed to advancement in human diagnostic imaging. They are currently approved for intravenous use in human and animal models. In this study we described intrathecal use in the horse. This study was undertaken to evaluate the reliability of standard and angle contrast-enhanced ultrasonography to detect and characterize surgically-induced longitudinal lesions in the deep digital flexor tendons.In this pilot study surgically-induced lesions were created in the lateral aspect of the deep digital flexor tendon within the digital flexor tendon sheath in 10 isolated equine limbs to generate a replicable model for naturally occurring lesions. Another 10 specimens were sham operated. All the limbs were examined ultrasonographically before and shortly after the intrasynovial injection of an ultrasound contrast agent containing stabilised microbubbles. The images were blindly evaluated to detect the ability to identify surgically-created lesions. The deep digital flexor tendons were dissected and a series of slices were obtained. The depth of longitudinal defects identified with contrast-enhanced ultrasound scans was compared to the real extent of the lesions measured in the corresponding gross tendon sections. RESULTS Contrast-enhanced ultrasonography with both angle and standard approach provided a significant higher proportion of correct diagnoses compared to standard and angle contrast ultrasonography (p < 0.01). Contrast-enhanced ultrasonography reliably estimated the depth of surgically-induced longitudinal lesions in the deep digital flexor tendons. CONCLUSION Contrast-enhanced ultrasound of the digital flexor tendon sheath could be an effective tool to detect intrasynovial longitudinal tears of the deep digital flexor tendon, although an in vivo study is required to confirm these results for naturally occurring lesions.
منابع مشابه
Computed Tomographic Tenography of Normal Equine Digital Flexor Tendon Sheath: An Ex Vivo Study
Aim of this study was to document the normal computed tomographic tenography findings of digital flexor tendon sheath. Six ex vivo normal equine forelimbs were used. An axial approach was used to inject 185 mg/mL of iopamidol in a total volume of 60 mL into the digital flexor tendon sheaths. Single-slice helical scans, with 5 mm thickness, spaced every 3 mm, for a pitch of 0.6, and with bone al...
متن کاملHistopathological and Biomechanical Survey on Effect of CoQ10 in Combination with Chitosan Conduit on Deep Digital Flexor Tendon Healing in Rabbits
Objective- Chitosan is of great interest in regenerative medicine because of its plentiful properties, like biocompatibility, biodegradability and non-toxicity. The objective of the present study was histopathological and biomechanical survey on effect of CoQ10 in combination with chitosan conduit on deep digital flexor tendon (DDFT) healing in rabbits. Design-</s...
متن کاملUltrasonography study of tendons and ligaments of metacarpal region in the camel (Camelus dromedarius)
Twelve left camel forelimbs were collected, and ultrasonography was performed at five different levels around the metacarpal region. Limbs were then cut in the transverse plane at levels corresponding to the ultrasound images. Transverse and sagittal plane images were taken at each of the five levels, keeping all ultrasound imaging factors constant. Echogenicity, diameter, width and cross secti...
متن کاملEffect of Ultrasound Therapy on the Hydroxyproline Content in Experimental Tendon Injuries in Horses.
Objective-To determine the effect of ultrasound therapy on hydroxyproline (HP) content in superficial digital flexor tendon (SDFT) in horses.Design - Experimental in vivo study.Animals - Eight adult castrated horses.Procedure- The mediocaudal surface of right metatarsal bone in was exposed and after complete separation of SDFT, it was splitted (striking 15 times) in full thickness in longitudin...
متن کاملTenosynovitis of the deep digital flexor tendon in horses.
TENOSYNOVITIS of the deep digital flexor tendon (thoroughpin) in horses is manifested by distention of its tarsal synovial sheath due to formation of an excessive synovial effusion. Unless tenosynovitis is acute, signs of inflammation, pain or lameness are absent (1). Tendinitis can and does occur in conjunction with inflammation of the tarsal synovial sheath. As tendons function they are frequ...
متن کامل