High-field diffusion MR histology: image-based correction of eddy-current ghosts in diffusion-weighted rapid acquisition with relaxation enhancement (DW-RARE).
نویسندگان
چکیده
High-resolution, diffusion-weighted (DW) MR microscopy is gaining increasing acceptance as a nondestructive histological tool for the study of fixed tissue samples. Spin-echo sequences are popular for high-field diffusion imaging due to their high tolerance to B(0) field inhomogeneities. Volumetric DW rapid acquisition with relaxation enhancement (DW-RARE) currently offers the best tradeoff between imaging efficiency and image quality, but is relatively sensitive to residual eddy-current effects on the echo train phase, resulting in encoding direction-dependent ghosting in the DW images. We introduce two efficient, image-based phase corrections for ghost artifact reduction in DW-RARE of fixed tissue samples, neither of which require navigator echo acquisition. Both methods rely on the phase difference in k-space between the unweighted reference image and a given DW image and assume a constant, per-echo phase error arising from residual eddy-current effects in the absence of sample motion. Significant qualitative and quantitative ghost artifact reductions are demonstrated for individual DW and calculated diffusion tensor images.
منابع مشابه
The eddy current distortion in the multiband diffusion images: diagnosis and correction
The diffusion weighted images acquired with the multiband sequence or the Lifespan protocols shows a type of slice distortion artifact. We find that this artifact is caused by the eddy currents, which can be induced by the diffusion gradient associated with either current DW image or the previous DW images. The artifact can be corrected by further tuning the compensation circuit in the MR hardw...
متن کاملCorrecting High Order Eddy Current Induced Distortion for Diffusion Weighted Echo Planar Imaging
INTRODUCTION It is well known that diffusion weighted echo planar imaging (DW-EPI) often suffers from direction dependent distortions due to diffusion gradient generated eddy currents. These distortions, if not corrected, can lead to misregistration among DW images of different directions and inaccuracies in any post processing operations involving DW image combination. Dual spin echo DW-EPI [1...
متن کاملGradient preemphasis calibration in diffusion-weighted echo-planar imaging.
This article describes a method which enables fast and objective pulse-sequence-specific preemphasis calibration, using standard pulse sequences and system hardware. The method is based on a k-space measurement technique, and has been applied to single-shot, diffusion-weighted, spin-echo, echo-planar imaging (DW-SE-EPI), which is particularly sensitive to eddy-current-induced image distortions....
متن کاملHigh efficiency, low distortion 3D diffusion tensor imaging with variable density spiral fast spin echoes (3D DW VDS RARE)
We present an acquisition and reconstruction method designed to acquire high resolution 3D fast spin echo diffusion tensor images while mitigating the major sources of artifacts in DTI-field distortions, eddy currents and motion. The resulting images, being 3D, are of high SNR, and being fast spin echoes, exhibit greatly reduced field distortions. This sequence utilizes variable density spiral ...
متن کاملConcurrent Field Monitoring Removes Distortions from In-Vivo DWI data
Introduction: In diffusion-weighted (DW) MRI, eddy current effects notoriously result in geometrical image distortions. This is problematic since variably diffusionencoded data must be perfectly congruent to permit fitting diffusion models such as the diffusion tensor. In modern MR systems extensive efforts are made to address this problem by optimized gradient coil and amplifier design, model-...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 61 3 شماره
صفحات -
تاریخ انتشار 2009