LocaLisa: new technique for real-time 3-dimensional localization of regular intracardiac electrodes.

نویسندگان

  • F H Wittkampf
  • E F Wever
  • R Derksen
  • A A Wilde
  • H Ramanna
  • R N Hauer
  • E O Robles de Medina
چکیده

BACKGROUND Estimation of the 3-dimensional (3D) position of ablation electrodes from fluoroscopic images is inadequate if a systematic lesion pattern is required in the treatment of complex arrhythmogenic substrates. METHODS AND RESULTS We developed a new technique for online 3D localization of intracardiac electrodes. Regular catheter electrodes are used as sensors for a high-frequency transthoracic electrical field, which is applied via standard skin electrodes. We investigated localization accuracy within the right atrium, right ventricle, and left ventricle by comparing measured and true interelectrode distances of a decapolar catheter. Long-term stability was analyzed by localization of the most proximal His bundle before and after slow pathway ablation. Electrogram recordings were unaffected by the applied electrical field. Localization data from 3 catheter positions, widely distributed within the right atrium, right ventricle, or left ventricle, were analyzed in 10 patients per group. The relationship between measured and true electrode positions was highly linear, with an average correlation coefficient of 0.996, 0.997, and 0.999 for the right atrium, right ventricle, and left ventricle, respectively. Localization accuracy was better than 2 mm, with an additional scaling error of 8% to 14%. After 2 hours, localization of the proximal His bundle was reproducible within 1.4+/-1.1 mm. CONCLUSIONS This new technique enables accurate and reproducible real-time localization of electrode positions in cardiac mapping and ablation procedures. Its application does not distort the quality of electrograms and can be applied to any electrode catheter.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of the LocaLisa mapping system during ablation procedures in patients with atrioventricular nodal reentrant tachycardia.

INTRODUCTION LocaLisa is a novel system for anatomical mapping. It enables an assessment of the three-dimensional position of electrodes within cardiac chambers without fluoroscopy. With this technique it may be possible to reduce radiation exposure during catheter-based ablation procedures. AIM To evaluate the efficacy and safety of ablation procedures performed using the LocaLisa mapping sy...

متن کامل

Reduction of fluoroscopy duration in radiofrequency ablation obtained by the use of a non-fluoroscopic catheter navigation system.

AIMS Radiofrequency (RF) ablation requires placement of several catheters at critical positions. The catheters are positioned with fluoroscopy, resulting in a significant radiation exposure. We have investigated to what degree an intracardiac navigation system reduces the fluoroscopy duration in different groups of routine RF ablations. METHODS AND RESULTS The fluoroscopy time was evaluated i...

متن کامل

The function ring functors of pointfree topology revisited

This paper establishes two new connections between the familiar function ring functor ${mathfrak R}$ on the category ${bf CRFrm}$ of completely regular frames and the category {bf CR}${mathbf sigma}${bf Frm} of completely regular $sigma$-frames as well as their counterparts for the analogous functor ${mathfrak Z}$ on the category {bf ODFrm} of 0-dimensional frames, given by the integer-valued f...

متن کامل

Localization of Eigenvalues in Small Specified Regions of Complex Plane by State Feedback Matrix

This paper is concerned with the problem of designing discrete-time control systems with closed-loop eigenvalues in a prescribed region of stability. First, we obtain a state feedback matrix which assigns all the eigenvalues to zero, and then by elementary similarity operations we find a state feedback which assigns the eigenvalues inside a circle with center   and radius. This new algorithm ca...

متن کامل

Prolapsing left atrial myxoma: preoperative diagnosis using a multimodal imaging approach with magnetic resonance imaging and real-time three-dimensional echocardiography.

Real-time three-dimensional echocardiography (RT3DE) is a new promising technique for the evaluation of intracardiac masses. We present the diagnostic work-up using a multimodal-imaging approach in a 74-year-old patient with a prolapsing tumour in the left atrium suggestive of a myxoma, causing severe congestive heart failure attributable to dynamic left ventricular inflow obstruction, and mimi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 99 10  شماره 

صفحات  -

تاریخ انتشار 1999