Evaluation of diagnostic device for obstructive sleep apnea.

نویسنده

  • David Cunnington
چکیده

The article by Bar et al (March 2003)1 reports an evaluation of the Watch PAT100 (WP100) device (Itamar Medical; Caesarea, Israel) for the diagnosis of obstructive sleep apnea. The manner in which the authors have presented their data does not adequately evaluate the accuracy of the WP100 device. The authors have used correlation and Bland-Altman plots to compare calculations of the apnea hypopnea index (AHI) derived from the WP100 and conventional attended polysomnography. Although a statistically significant correlation was found, this does not imply agreement between the two measurements. The finding that there is a statistically significant relationship between the two measurements is not surprising as they are measuring the same thing. The real question is by how much measurements using the new method differ from the old. For this reason, Bland and Altman2 described the use of Bland-Altman plots to assess agreement. A critical part of this analysis is the calculation of the mean difference between the measurements and the limits of agreement ( 2 SDs) and plotting these on the graph. Used in this way the Bland-Altman plot gives a measure of agreement that allows the evaluation of the agreement between two measurements over a range of values. Bar et al1 have included a Bland-Altman plot in their article, but failed to include the mean difference or the limits of agreement. From visual inspection of the data, it appears that there is a large difference between measurements, with the WP100 underscoring events at low AHIs and overscoring events at high AHIs. They report “good agreement” and a “slight tendency” to underscore and overscore events. However, given that the magnitude of the difference between the two measurements is as large as 45 events per hour, with many other points being 10 events per hour, I do not agree with their conclusions. Differences of this magnitude are clinically significant and impact on the diagnosis and treatment of patients. The lack of important data in this article assessing a new diagnostic device reminds us all of the importance of careful evaluation of new technologies before integrating them into clinical practice. Hopefully the initiatives of the Standards for Reporting of Diagnostic Accuracy group will help to improve reporting of new diagnostic techniques in the future.3

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Biofeedback Therapy on Cardiovascular and Respiratory Indices in NREM Sleep Parasomnias with Obstructive Sleep Apnea: A Case study

Introduction: Non-REM parasomnias are a relatively common condition in the general human population. Current treatment plans are usually based on small case series and reports. Considering the effects of sleep disorders on different aspects of human life and the failure of pharmacological treatments in this field, the present study was designed to investigate a case of this sleep disorders with...

متن کامل

Prolonged Sleep Apnea in Two Patients with a History of Opium Abuse-A Case Report

Introduction: Obstructive sleep apnea (OSA) is a highly prevalent sleep-disordered breathing (SDB).   Case Report: Two 53- and 51-year-old male cases with daytime sleepiness and opium abuse and severe sleep apnea and long respiratory events duration (200 and 275 seconds respectively) noted in polysomnography were reported at Ebn-e-Sina and Razavi hospita...

متن کامل

Apert Syndrome with Obstructive Sleep Apnea: A Case Report

Apert syndrome is a rare kind of craniosynostosis which is identified with fusion of cranial sutures during prematurity period and causes physical and intellectual disorders in younger ages. These patients may show symptoms of obstructive sleep apnea due to abnormal craniofacial shape. This article introduces a patient with Apert syndrome, with apnea symptoms, cyanosis, snoring, restlessness, n...

متن کامل

Determination of The Relationship Between Severity of Obstructive Sleep Apnea And Chronic Obstructive Pulmonary Disease

Introduction: Chronic obstructive pulmonary disease (COPD) patients are at increased risk of sleep-disorders. The concomitant occurrence of COPD and obstructive sleep apnea hypopnea syndrome (OSAHS) is named overlap syndrome. This study aimed to evaluate the severity of OSAHS in overlap syndrome patients.Materials & Methods: This cross-sectional study was conducted on adult patients with forced...

متن کامل

A survey on the relationship between obstructive sleep apnea and difficult intubation in the elderly

Background and Objectives: Difficult intubation is one of the challenges for patients undergoing anesthesia that leads to severe complications and death. Obstructive sleep apnea is one of the factors that may be associated with difficult intubation. The present study was carried out to investigate the relationship between obstructive sleep apnea and difficult intubation in the elderly. Mater...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chest

دوره 124 4  شماره 

صفحات  -

تاریخ انتشار 2003