Prolene monofilament suture in Boston Keratoprosthesis surgery.
نویسندگان
چکیده
Toxic reaction to nylon following uncomplicated cataract surgery and vitrectomy has been documented in the literature. We report the case of an aniridic patient with a known adverse reaction to nylon in whom Prolene suture was used in Boston Keratoprosthesis type 1 (KPro) surgery. During follow-up the cornea was checked for signs of inflammation and toxic reaction; at last follow-up (18 months) the patient showed no signs of complications due to Prolene. Our study suggests that Prolene suture may be used as an alternative to nylon in Boston KPro surgery in patients with a history of nylon toxicity.
منابع مشابه
Comparative study of skin closure in dogs with polypropylene and polyglactin 910
The primary purpose of tissue reconstruction is to connect separated wound edges. Proper selection of sutures helps achieve better results in skin surgery. Polypropylen (Prolene®) and polyglactin 910 (Vicryl rapid®) were observed and compared for use in veterinary skin surgery. The handling characteristics of Prolene® suture is less satisfactory then Vicryl rapid® suture because of the stiffnes...
متن کاملMaxon is an Optimal Suture for Bile Duct Anastomoses in Pigs
BACKGROUND Three commonly used sutures were tested in a pig model of bile duct anastomosis to assess their relative contributions to inflammation and scarring. METHODS Thirty pigs were randomised to bile duct division and anastomosis with either polyglyconate (Maxon), polyglactin 910 (Vicryl) or polypropylene (Prolene). Half the animals were sacrificed at two weeks and the remainder at 23 wee...
متن کاملArgon laser suture lysis with different suture materials. An experimental study.
In an in vitro study, 10/0 nylon was found to require a significantly lower laser energy density to produce suture lysis following a single shot than either 10/0 Dacron or 10/0 prolene. Nylon and Dacron monofilament sutures ruptured at reproducible energy levels without significant observable changes at subthreshold irradiation. Prolene, however, was observed to stretch at energy levels below t...
متن کاملCost-effectiveness of the Boston keratoprosthesis.
PURPOSE To conduct a cost-utility analysis and determine the cost-effectiveness of the Boston Keratoprosthesis (Boston Kpro). DESIGN Retrospective cohort study. METHODS setting: The Massachusetts Eye and Ear Infirmary corneal service. patients: Inclusion required a minimum 2-year follow-up. Patients with autoimmune diseases and chemical burns were excluded. Eighty-two patients were included...
متن کاملMechanical Properties of Polyglycolide-trimethylene Carbonate and Polydioxanone Monofilament Sutures in Vivo Used for Flexor Tendon Repair
INTRODUCTION Braided polyester suture materials have been commonly used for flexor tendon repair in the clinical setting. However, knotted braided polyester lost approximately 50% of its tensile strength according to a study by Trail et al.(1) Accordingly, 4 or 5 throws are needed to prevent slippage for a secure knot, which may result in stitch granuloma. The use of absorbable sutures avoids p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Digital journal of ophthalmology : DJO
دوره 17 1 شماره
صفحات -
تاریخ انتشار 2011