چکیده

Three commercially available real-time reverse transcriptase PCR assays (the Artus RealArt HPA coronavirus LightCycler, the Artus RealArt HPA coronavirus Rotor-Gene, and the EraGen severe acute respiratory syndrome coronavirus POL assay) and three RNA extraction methodologies were evaluated for the detection of severe acute respiratory syndrome coronavirus RNA from 91 stool specimens. The assays' sensitivities were highest (58% to 75%) for specimens obtained 8 to 21 days after symptom onset. The assays were less sensitive when specimens were obtained less than 8 days or more than 21 days after the onset of symptoms. All assays were 100% specific.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preclinical evaluation of two real-time, reverse transcription-PCR assays for detection of the severe acute respiratory syndrome coronavirus.

We verified the analytical performance characteristics of a previously described real-time reverse transcription-PCR (RT-PCR) assay targeting the open reading frame (ORF) 1b region of the severe acute respiratory syndrome coronavirus (SARS-CoV) with RNA transcripts. We then compared it to a novel nucleocapsid gene real-time RT-PCR assay with genomic RNA. The assays differed only in the primer a...

متن کامل

Performance of single-step gel-based reverse transcription-PCR (RT-PCR) assays equivalent to that of real-time RT-PCR assays for detection of the severe acute respiratory syndrome-associated coronavirus.

Simple gel-based one-step reverse transcription-PCR (RT-PCR) assays, used to investigate patients during the 2003 severe acute respiratory syndrome (SARS) outbreak in Singapore, were found to be as sensitive as commercial and in-house real-time RT-PCR assays. The detection limit was approximately 1 genome equivalent (GE) per 5 microl PCR mixture. One PFU of SARS coronavirus was estimated to be ...

متن کامل

Evaluation of real-time reverse transcriptase PCR and real-time loop-mediated amplification assays for severe acute respiratory syndrome coronavirus detection.

We compared the performance of a recently established real-time loop-mediated amplification (LAMP) assay with the one from a highly sensitive quantitative PCR assay. None of these assays produced false-positive results in this study. For samples isolated from patients within the first 3 days of disease onset, the detection rate of the quantitative PCR assay was higher (14 of 15 were positive) t...

متن کامل

Clinical evaluation of real-time PCR assays for rapid diagnosis of SARS coronavirus during outbreak and post-epidemic periods.

BACKGROUND The protocols of WHO network laboratories facilitated development of rapid diagnosis for SARS coronavirus (CoV) using reverse transcription (RT)-PCR assays. However, several reports have shown that conventional and real-time PCR assays were very specific for SARS CoV but lack sensitivity depending on the assay, specimen, and time course of disease. OBJECTIVE To evaluate an automati...

متن کامل

Real-Time Reverse Transcription–Polymerase Chain Reaction Assay for SARS-associated Coronavirus

reaction (RT-PCR) assay was developed to rapidly detect the severe acute respiratory syndrome–associated coronavirus (SARS-CoV). The assay, based on multiple primer and probe sets located in different regions of the SARSCoV genome, could discriminate SARS-CoV from other human and animal coronaviruses with a potential detection limit of <10 genomic copies per reaction. The real-time RTPCR assay ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 44 11  شماره 

صفحات  -

تاریخ انتشار 2006