False-positive immunoassay results: a multicenter survey of erroneous immunoassay results from assays of 74 analytes in 10 donors from 66 laboratories in seven countries.
نویسنده
چکیده
BACKGROUND Analytical interference in immunoassays can produce serious errors, but it is generally considered rare with modern analytical systems. METHOD Blood was collected from 10 donors with illnesses known to be associated with rheumatoid factor. Immunoassays for 74 analytes were performed in 66 clinical laboratories. Each sample was measured in duplicate, and again in duplicate after the addition of a proprietary heterophil blocking reagent, with the laboratory's routinely used reagents and equipment. Reagents were typically supplied by the manufacturers of the closed analytical systems. Both competitive and sandwich immunoassays were investigated. RESULTS Overall approximately 8.7% of the 3445 results were considered to be "false positive", many of them seriously so. Twenty-one percent of the erroneously high results (1.8% of all results) were potentially misleading and were corrected by blocking reagent, although 49% of such seriously high results (4.2% of all results) were not. A further 39% of the false-positive results (2.6% of all results) would not necessarily have appeared likely to produce adverse clinical consequences but were substantially lowered by the addition of the blocking reagent. CONCLUSIONS Random errors can occur with all types of immunoassays tested and can be difficult to identify even when repeated in another laboratory. Clinicians need to be aware of these limitations.
منابع مشابه
Increased serum concentrations of intestinal alkaline phosphatase in peritoneal dialysis.
References 1. Foon KA, John WJ, Chakraborty M, Das R, Teitelbaum A, Garrison J, et al. Clinical and immune responses in resected colon cancer patients treated with anti-idiotype monoclonal antibody vaccine that mimics the carcinoembryonic antigen. J Clin Oncol 1999;17:2889–95. 2. Whitley RJ. Thyroid function. In: Burtis CA, Ashwood ER, eds. Tietz textbook of clinical chemistry, 3rd ed. Philadel...
متن کاملLatex agglutination and enzyme-linked immunosorbent assays for cytomegalovirus serologic screening of transplant donors and recipients.
The effectiveness of three serologic assays (two enzyme-linked immunosorbent assays [ELISAs] and latex agglutination) for cytomegalovirus (CMV) serologic matching of donors and recipients was assessed over a 2-year period in a major organ transplant program. Sera with equivocal test results were investigated by repeat testing of serum samples and additional specimens from the individuals involv...
متن کاملRetraining over the principles and mechanisms involved in the occurrence of false results from urine drug screening tests: Adulteration and strategies to defeat
Screening tests (UDSTs) for the diagnosis of psychoactive drugs can identify drug abuse, improve workplace safety, ensure community health, and play a critical role in therapeutic drug monitoring. Nonetheless, correct interpretation of the results of these tests requires a full awareness of the principles of testing methods, drug kinetics, and various leading causes of false results. Among the ...
متن کاملComparison of Western blotting and PCR assays for confirmation of HTLV-1 virus in volunteer blood donors
Abstract Background and Objectives Human T-cell lymphotropic virus type I (HTLV-I) has been associated with two diseases in humans such as adult T-cell leukemia/lymphoma (ATLL) and HTLV-associated myelopathy/tropical spastic Para paresis (HAM/TSP). About 5 to 10 million people are infected with HTLV-1 worldwide. In order to improve the blood safety and to prevent false positive results in bloo...
متن کاملLot-to-lot variations in a qualitative lateral-flow immunoassay for chronic pain drug monitoring.
Recently, Algeciras-Schimnich et al. highlighted the lot-to-lot variability of a quantitative immunoassay and the failure of frequently used protocols to detect these variations (1). We have discovered that lot-to-lot variations also present an important issue in qualitative immunoassays used for chronic pain monitoring. These variations impact the reliability of these assays in clinical practi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 48 11 شماره
صفحات -
تاریخ انتشار 2002