Imaging with the MAMA Detector : Preliminary Results
نویسنده
چکیده
We report on the first successful speckle imaging studies using the Stanford University speckle interferometry system, an instrument that uses a multianode microchannel array (MAMA) detector as the imaging device. The method of producing high-resolution images is based on the analysis of so-called “near-axis” bispectral subplanes and follows the work of Lohmann et al. (1983). In order to improve the signal-to-noise ratio in the bispectrum, the frame-oversampling technique of Nakajima et al. (1989) is also employed. We present speckle imaging results of binary stars and other objects from V magnitude 5.5 to 11, and the quality of these images is studied. While the Stanford system is capable of good speckle imaging results, it is limited by the overall quantum efficiency of the current MAMA detector (which is due to the response of the photocathode at visible wavelengths and other detector properties) and by channel saturation of the microchannel plate. Both affect the signal-to-noise ratio of the power spectrum and bispectrum.
منابع مشابه
Scientific Requirements for Thermal Control and Scheduling of the STIS MAMA detectors after SM-3
The installation of the Aft Shroud Cooling System (ASCS) on the next HST servicing mission will increase the scientific productivity of STIS by reducing the dark current in the MAMA detectors. The “dark glow” now observed in the FUV-MAMA detector is expected to go away at the ~24 ο C nominal operating temperature after SM3. For the NUV-MAMA, typical dark currents will range from 800 to 1100 cts...
متن کاملSimulation of a Neutron Detector for Real Time Imaging Applications
Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...
متن کاملAbsolute Flux Calibration of STIS MAMA Imaging Modes
The absolute flux calibration of STIS MAMA imaging modes is tested by comparison of observed and predicted count rates. As part of this work, we have derived new, wavelength-dependent aperture corrections for MAMA imaging, and have revised the NUVMAMA imaging throughput at short wavelengths. FUV-MAMA imaging modes clearly show a time dependent sensitivity loss that is consistent with the time d...
متن کاملPreliminary study on the properties of zinc oxide (ZnO) for alpha particles detection
Background: : Due to the difficulties of locally obtaining ZnS(Ag), preliminary investigation of the radioluminescence characterization of Zinc oxide (ZnO) for alpha particle detection was performed. Materials and Methods: The scintillation properties of ZnO films were tested using alpha sources  ...
متن کاملPhyllodes Tumor of the Breast: 307 Treated Cases, the Largest Mexican Experience at a Single Breast Disease Institution
Background: Phyllodes tumor (PT) of the breast in Hispanic patients is more frequently reported with large tumors and with more borderline/malignant subtypes compared with other populations. The objective of this study was to describe characteristics of patients with PT and to identify differences among subtypes in a Mexican population. <...
متن کامل