Lumbar epidural analgesia in labour: relation to fetal malposition and instrumental delivery.
نویسندگان
چکیده
The incidence of instrumental delivery and malposition immediately before delivery was compared in patients who were given lumbar epidural analgesia and those who were not. Instrumental delivery was five times more common and a malposition of the fetal head was more than three times as common in the epidural group as in women who did not receive regional analgesia. Similar incidences were found even when the epidural was electively chosen before labour in the absence of medical indications. The instrumental delivery rate was affected by parity, the length of the second stage of labour, and the return of sensation by the second stage but not by other factors studied. The high incidence (20%) of malposition associated with epidural analgesia was not affected by any of the factors studied. The psychological and physical disadvantages of malposition and instrumental delivery have yet to be assessed. In the meantime, when there are no medical indications for epidural analgesia, the advantages of pain relief should be weighed against those of a normal spontaneous delivery.
منابع مشابه
مقایسه میزان بیدردی در سیر زایمان در دو روش اسپانیال (با استفاده از سوفنتانیل) و اپیدورال(با استفاده از بوپوواکائین و لیدوکائین)
Background and purpose: This study was designed in order to compare the effects of spinal and epidural analgesia on labour and also several maternal and fetal factors in vaginal delivery. Materials and Methods: The study was a randomized clinical trail and participatnts were 120 gravid 1 and gravid 2 women in the active phase of delivery, admitted to the labour room of Fatemieh Hospital in...
متن کاملOxytocin infusion during second stage of labour in primiparous women using epidural analgesia: a randomised double blind placebo controlled trial.
OBJECTIVE To determine whether the high rate of forceps delivery associated with the use of epidural analgesia could be reduced through giving an intravenous infusion of oxytocin during the second stage of labour. DESIGN A randomised, double blind, placebo controlled trial. SETTING Delivery suites in three hospitals. SUBJECTS 226 Primiparous women with adequate epidural analgesia in whom ...
متن کاملFluid loading to reduce abnormalities of fetal heart rate and maternal hypotension during epidural analgesia in labour.
Fetal heart rate (FHR) was recorded and maternal blood pressure measured in 104 patients in whom lumbar epidural analgesia was induced in labour. Fifty-one patients received an intravenous load of 11 of Hartmann's solution immediately before the epidural injection. This infusion significantly reduced the incidence of abnormalities of FHR from 34% to 12% and of maternal hypotension from 28% to 2...
متن کاملThe Effect of Epidural Analgesia on the Delivery Outcome of Induced Labour: A Retrospective Case Series
Objective. To investigate whether the use of epidural analgesia during induced labour was a risk factor for instrumental vaginal delivery and caesarean section (CS) delivery. Study Design. This was a retrospective case series of primigravidae women being induced at term for all indications with a normal body mass index (BMI) at booking and under the age of 40 years. Results. We identified 1,046...
متن کاملTHE EFFECT OF INTRAPARTUM EPIDURAL ANALGESIA ON NULLIPAROUS LABOR
Our purpose was to determine the effect of epidural analgesia on nulliparous labor and delivery. Nonnal term nulliparous women in spontaneous labor were divided into two groups in a quazi-experimental study, 100 in each group. The first group received epidural analgesia and the second had no analgesia at all. In the first group, an epidural catheter was placed in 3-4 cm cervical dilatation ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British medical journal
دوره 1 6052 شماره
صفحات -
تاریخ انتشار 1977