Contamination of Dental Unit Water and Air Outlets Following Use of Clean Head System and Conventional Handpieces

نویسندگان

  • Lida Toomarian
  • Sahand Rikhtegaran
  • Mehrnoosh Sadighi
  • Siavash Savadi Oskoee
  • Parnian Alizadeh Oskoee
چکیده

BACKGROUND AND AIMS Dental handpiece is a source of contamination because it is in constant touch with the oral cavity. Sterilization does not seem to be sufficient to prevent penetration of microorganisms into air and water lines of the unit, because negative pressure developed by valves (which are placed in water outlets) and post shut-off inertial rotation of handpiece result in water and debris being sucked into air and water outlets of dental unit. The aim of this study was to compare dental unit contamination following use of clean head system handpieces and conventional handpieces. MATERIALS AND METHODS Twenty-two dental units in the Department of Pediatric Dentistry in Shahid Beheshti Faculty of Dentistry were used for the purpose of this study. A 1.5×108 cfu/mm3 concentration of Staphylococcus epidermis (SE) was used to contaminate the air and water outlets of dental units. Ten clean head system handpieces and 10 conventional handpieces were used for 30 seconds in the above-mentioned suspension. Microbial samples were collected from the air and water lines. Culturing and colony counting procedures were carried out. Data was analyzed by t-test; a value of p<0.01 was considered significant. RESULTS Results demonstrated a significantly lower SE contamination in water outlets following the use of clean head system (p<0.01). CONCLUSION A lower tendency of clean head system handpieces to transmit SE compared to conventional system makes them a better choice for infection control.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی آلودگی میکروبی سیستم‌های آبی یونیت‌های دندانپزشکی بخش تخصصی ترمیمی دانشکده دندانپزشکی دانشگاه علوم پزشکی تهران در سال 1385

Background and Aim: According to infection possibility in high risk patients, assessment of microbial contamination in water sources utilized at medico-dental units has become a recent concern. The purpose of this study was to evaluate the microbial contamination in dental units waterlines at the department of operative dentistry, Tehran university of medical sciences in the year 2006. Materia...

متن کامل

The in vivo contamination of air-driven low-speed handpieces with prophylaxis angles.

BACKGROUND The authors conducted an in vivo study to determine if low-speed handpiece motors can become contaminated with oral flora when used with prophylaxis angles. METHODS This crossover study involved 20 subjects, two types of handpieces and three prophylaxis angles. The authors used each handpiece/prophylaxis angle system to polish teeth. They then collected samples, spiral-plated the s...

متن کامل

Bactericidal effects of acidic electrolyzed water on the dental unit waterline.

Many studies have been conducted in the United States regarding the microbial contamination of dental unit waterline, but not in Japan. Recently, acidic electrolyzed water has been used in the medical and dental fields. In this study, we investigated the bactericidal effects of the temporary inflow of acidic electrolyzed water on microbial contamination of the dental unit waterline. First, in o...

متن کامل

Evaluation of activities aimed at preventing microbiological risks in dental practice.

BACKGROUND Microbiological contamination of water in dental unit waterlines (DUWL) creates a risk of cross-infections, and is a source of biological risk factors in the work environment of a dentist. The aim of the study was to evaluate dentists' knowledge on DUWL microbiological contamination and the scope of activities/procedures they undertake to monitor it. MATERIALS AND METHOD The questi...

متن کامل

Frequency evaluation of Pseudomonas SPP contamination in the dental unit water line system at Mashhad dental school

Background and aim: One of the well-known bacteria in dental unit water contamination is Pseudomonas aueroginosa. The aim of the present study was to evaluate the amount of Pseudomonas aeruginosa species infection in the dental unit water samples of Dental Faculty of Mashhad University of Medical Sciences. Material and methods: Water samples collected randomly from the turbines of 10% of the ac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2007