Clinical documentation on ASTRA TECH Implant System
ثبت نشده
چکیده
The OsseoSpeed implant (also including short, narrow and Profile implants) has been extensively documented in several prospective clinical studies covering most indications such as: single-tooth restorations, fixed partial/full prostheses, and overdentures with a minimum of 1 year of follow-up . Moreover, results show that the implant can be safely used with a survival rate ranging from 94.5 to 100% 9–29, 97, 103, . The same good results are reported for immediate loading protocols in the atrophic maxilla , in sinus lifted/grafted sites 33–43 and after immediate installation in extraction sockets 14–16, 20, 44–49, . Additionally, several studies have reported on good esthetics 20, 49, 54–58 and high patient satisfaction 15, 27, 28, .
منابع مشابه
Clinical documentation on ASTRA TECH Implant System
Prospective clinical data reporting on the ASTRA TECH Implant System OsseoSpeed implant shows that it can be safely used in a variety of indications in the maxilla and mandible, with a reported survival rate ranging from 94.5 to 100% , with only one exception . The same good results are reported for immediate loading protocols in the atrophic maxilla 17, , in sinus lifted/grafted posterior site...
متن کاملScientific Review: Conical Seal Design
A key feature of the ASTRA TECH Implant System BioManagement Complex is the design of the implant-abutment connection, i.e. the Conical Seal Design. This design feature has been part of the implant system since 1985, thus all clinical documentation available includes results on this key feature. This review includes technical literature focusing on evaluating the Conical Seal Design, using appr...
متن کاملSurvival rate of Astra Tech implants with maxillary sinus lift
OBJECTIVES The aim of this study was to retrospectively evaluate the clinical survival rate of Astra Tech implants in the maxillary molar region performed with sinus lift and bone graft. MATERIALS AND METHODS Ninety-nine Astra Tech implants (Osseospeed) placed in the maxillary molar region using sinus lift from September 2009 to February 2012 were selected with a minimum follow-up period of 1...
متن کاملAstra Tech and Brånemark system implants: a 5-year prospective study of marginal bone reactions.
This paper describes the 5-year results of a comparative study between Astra Tech and Brånemark system implants. The aim was to compare the systems primarily with regard to bone level changes, and also with regard to other variables of interest. Sixty-six patients with edentulous jaws were included in the study. Randomisation schedules were used to allocate the patients to the two implant syste...
متن کاملEffect of microthread on the maintenance of marginal bone level: a 3-year prospective study.
OBJECTIVES The purpose of the present study was to evaluate the long-term effect of the microthread on the maintenance of marginal bone level. MATERIAL AND METHODS Seventeen patients were selected and two types of Astra Tech implants were installed, with the Microthread on the coronal portion of the fixture [Astra Tech Single Tooth Implant (ST)] or without the Microthread [Astra Tech TiOblast...
متن کامل