The addition of a pH-sensitive gel improves microemulsion stability for the targeted removal of colonic ammonia

نویسندگان

  • Ai-Hong Wang
  • Zhi-Jun Duan
  • Ge Tian
  • Dan Lu
  • Wen-Jun Zhang
  • Gao-Hong He
  • Gui-Hua Fang
چکیده

BACKGROUND We prepared an oral W/O microemulsion for the removal of colonic ammonia (ME-RCA). The effect of this microemulsion was influenced by the digestion process in the gastrointestinal tract. In this paper, we aim to show that stability was improved by using a microemulsion-based gel for the removal of colonic ammonia (MBG-RCA). METHODS MBG-RCA was prepared by adding sodium alginate to the ME-RCA. MBG-RCA and ME-RCA were passed through a simulated gastrointestinal environment, and the amount of colonic ammonia present was then determined by titration with a standard solution of hydrochloric acid. The pH of the gastrointestinal fluid was measured using a pH test paper and the size and form of the microemulsions were examined under the microscope. 18 healthy rats were randomly divided into three groups, fasted for 24 hours and allowed to drink normally. Three-way pipes were placed at the gastroduodenal junction in Group I, and at the terminal ileum in Group II. After the intragastric administration of ME-RCA, the stomach contents in Group I, the effluent from the terminal ileum in Group II and discharge from the anus in Group III were collected. The pH values of the gastrointestinal juice were measured by the pH test paper and those of the colon were determined by a universal indicator. These animal experiments were also used to test the effect of MBG-RCA. RESULTS MBG-RCA showed a better removal rate of artificial colonic ammonia than ME-RCA (P < 0.05). The decrease in pH value of the artificial small intestinal fluid due to ME-RCA did not occur when MBG-RCA was used. In the simulated gastrointestinal process, MBG-RCA maintained greater stability and released the emulsion (ME-RCA) in the colonic fluid. In the gastrointestinal tract of normal SD rats, ME-RCA decreased in size and lost its stable form after entering the small intestine, while MBG-RCA remained stable and intact emulsion-drops were observed from the anus. Neither substance had any effect on the pH of the stomach or colon of normal rats (partly because normal rats were fasted for 24 hours and allowed to drink normally, which resulted in a low level of ammonia production in the colon). Unlike ME-RCA, MBG-RCA did not reduce the pH of the small intestine. CONCLUSIONS MBG-RCA was more stable in the gastrointestinal tract and more effective at removing colonic ammonia when a higher concentration of ammonia was present. This made it possible to achieve the targeted removal of colonic ammonia and is a promising method to prevent hepatic encephalopathy (HE) in future studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

pH-sensitive microemulsion-based gels for removal of colonic ammonia: a novel preventative oral preparation for hepatic encephalopathy in rats.

Microemulsions with limited stability in mimetic gastrointestinal environments have previously demonstrated potential for the effective removal of ammonia from artificial colonic fluid. Specialized pH‑sensitive microemulsion‑based gels for the removal of colonic ammonia (MBG‑RCA), however, possess relative stability in the gastrointestinal (GI) tract of normal rats, indicating potential use in ...

متن کامل

SUSPENSION STABILITY OF TITANIA NANOPARTICLES STUDIED BY UV-VIS SPECTROSCOPY METHOD

Ultraviolet–Visible (UV–Vis) spectroscopy was used, in the current investigation, to explore the dispersion and stability of titania nanoparticles in an aqueous media with different types of dispersants. Hydrochloric and nitric acids as well as ammonia were used to determine the stability of the suspension in the acidic region (pH=2.5) and basic area (pH=9.5), respectively. In addition, for mea...

متن کامل

Preparation and characterization of bear bile-loaded pH sensitive in-situ gel eye drops for ocular drug delivery

Objective(s): In this study, a stable bear bile-loaded pH sensitive in-situ eye drop gel was prepared for sustain delivery and enhanced therapeutic application. Materials and Methods: Bear bile-loaded in-situ ocular gels with different Carbopol/Hydroxypropyl methylcellulose (HPMC)  ratios were prepared and their stability was tested in P...

متن کامل

Addition of Fillers to Sodium Alginate Solution Improves Stability and Immobilization Capacity of the Resulting Calcium Alginate Beads

Background: Although advantages of immobilization of cells through entrapment in calcium alginate gel beads have already been demonstrated, nevertheless, instability of the beads and the mass transfer limitations remain as the major challenges.Objective: The objective of the present study was to increase the stability, porosity (reduce mass transfer limit...

متن کامل

The effects of operating factors on the removal of total ammonia nitrogen and florfenicol antibiotic from synthetic trout fish farm wastewater through nanofiltration

An aquaculture system can be a potentially significant source of antibacterial compounds and ammonia in an aquatic environment. In this study, the removal of total ammonia nitrogen and florfenicol antibiotic from synthetic aqueous wastewater was assessed by applying a commercial TFC (thin film composite) polyamide nanofilter. The effects of pH (6.5-8.5), pressure (4-10 bar), concentration of to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2011