A new approach to compensate the geometric distortion in the synthetic aperture ultrasonic imaging system.

نویسندگان

  • Xiaonian He
  • Weixiang Liu
  • Siping Chen
  • Zhengdi Qin
چکیده

In the field of ultrasonic imaging technology, the problem of geometric distortion is often encountered, especially in the ultrasonic near-field. In this study, a new approach is proposed to compensate for geometric distortion in the synthetic aperture ultrasonic imaging system. This approach is based on the synthetic aperture ultrasonic holographic B-scan (UHB) imaging system, which is a combination of ultrasonic holography based on the backward propagation principle and the conventional B-scan technique. To solve the geometric distortion problem, the operation of the spatial compression and resampling in the frequency domain are introduced. The main advantage of the approach is that the real holographic value can be calculated without distortion by using the spatial interpolation function after the spatial frequency compression. After the compensation for geometric distortion is performed, the synthetic aperture technique based on the backward propagation principle is then applied in the process of the two-dimensional numerical imaging reconstruction. Both the simulation and measurement experiment show that the approach is promising. The geometric distortion that is dependent on the wave front angle can be effectively compensated. The spatial resolution is practically uniform throughout the depth range and close to the theoretical limit in the experiments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System

Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...

متن کامل

Improving the quality of ultrasound images using Bayesian estimators

Medical ultrasound imaging due to close behavior of cancer tumors to body tissues has a low contrast. This problem with synthetic aperture imaging method has been addressed. Although the synthetic aperture imaging technique solved the low-contrast problem of ultrasound images, to an acceptable limit, but the performance of these methods is not even acceptable when the signal to noise ratio (SNR...

متن کامل

Geometric distortion evaluation of magnetic resonance images by a new large field of view phantom for magnetic resonance based radiotherapy purposes

Background: The magnetic resonance imaging (MRI)-based radiotherapy planning method have been considered in recent years because of the advantages of MRI and the problems of planning with two images modality. The first step in MRI-based radiotherapy is to evaluate magnetic resonance (MR) images geometric distortion. Therefore, the present study aimed to evaluate system related geometric distort...

متن کامل

Assessment of Reproducibility of Geometric Distortion in MRI using Phantom Measurements

Introduction:  Image  distortion  is  one  of  the  major  problems  of  magnetic  resonance  imaging  (MRI) for use in 3DMRI, velocity MRI, FMRI and radiotherapy treatment planning (RTTP). It is  widely known that the most obvious effect of the inhomogenity of the magnetic fields and the  nonlinearity  of  the  gradient  is  the  Geometric  Distortion  of  MR  tomograms.  In  this  study,  the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bio-medical materials and engineering

دوره 26 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2015