Evaluation of pump pulsation in respirable size-selective sampling: part I. Pulsation measurements.
نویسندگان
چکیده
Pulsations generated by personal sampling pumps modulate the airflow through the sampling trains, thereby varying sampling efficiencies, and possibly invalidating collection or monitoring. The purpose of this study was to characterize pulsations generated by personal sampling pumps relative to a nominal flow rate at the inlet of different respirable cyclones. Experiments were conducted using a factorial combination of 13 widely used sampling pumps (11 medium and 2 high volumetric flow rate pumps having a diaphragm mechanism) and 7 cyclones [10-mm nylon also known as Dorr-Oliver (DO), Higgins-Dewell (HD), GS-1, GS-3, Aluminum, GK2.69, and FSP-10]. A hot-wire anemometer probe cemented to the inlet of each cyclone type was used to obtain pulsation readings. The three medium flow rate pump models showing the highest, a midrange, and the lowest pulsations and two high flow rate pump models for each cyclone type were tested with dust-loaded filters (0.05, 0.21, and 1.25mg) to determine the effects of filter loading on pulsations. The effects of different tubing materials and lengths on pulsations were also investigated. The fundamental frequency range was 22-110 Hz and the magnitude of pulsation as a proportion of the mean flow rate ranged from 4.4 to 73.1%. Most pump/cyclone combinations generated pulse magnitudes ≥10% (48 out of 59 combinations), while pulse shapes varied considerably. Pulsation magnitudes were not considerably different for the clean and dust-loaded filters for the DO, HD, and Aluminum cyclones, but no consistent pattern was observed for the other cyclone types. Tubing material had less effect on pulsations than tubing length; when the tubing length was 183cm, pronounced damping was observed for a pump with high pulsation (>60%) for all tested tubing materials except for the Tygon Inert tubing. The findings in this study prompted a further study to determine the possibility of shifts in cyclone sampling efficiency due to sampling pump pulsations, and those results are reported subsequently.
منابع مشابه
Evaluation of pump pulsation in respirable size-selective sampling: Part III. Investigation of European standard methods.
Lee et al. (Evaluation of pump pulsation in respirable size-selective sampling: part I. Pulsation measurements. Ann Occup Hyg 2014a;58:60-73) introduced an approach to measure pump pulsation (PP) using a real-world sampling train, while the European Standards (EN) (EN 1232-1997 and EN 12919-1999) suggest measuring PP using a resistor in place of the sampler. The goal of this study is to charact...
متن کاملOptimum Design of BrushLess DC Motor with Minimum Torque Pulsation using FEM & PSO
Despite many advantages of BrushLess DC motor, torque pulsation is one of the most important disadvantages of it. At first, an optimum primary design of BLDC motor is done using PSO algorithm. Then, other parameters for reducing the torque pulsation are considered by finite element method. It is shown that fractional slot structure has many advantages than conventional one. Both cogging and rip...
متن کاملLINEAR PULSATION CHARACTERISTICS OF MIRA VARIABLE STARS
The linear adiabatic pulsation-periods of Mira variable stars have been derived. Approximately 2701[1]models were calculated for M = 0.7 MΘ to 2 MΘ stars with radii from 180 RΘ to 340 RΘ and luminosities from 2800 LΘ to 10,000 LΘ. The chemical composition of all models is (X,Z) = (0.7,0.02). From the result of this study, linear relations on Luminosity-Period-Mass relationship and luminosity-pe...
متن کاملAngular Size Measurements of Mira Variable Stars at 2.2 Microns. Ii
We present angular size measurements of 22 oxygen-richMira variable stars. These data are part of a longterm observational program using the Infrared Optical Telescope Array to characterize the observable behavior of these stars. Complementing the infrared angular size measurements, values for variable star phase, spectral type, bolometric flux, and distance were established for stars in the sa...
متن کاملAngular Size Measurements Of Mira Variable Stars At 2 . 2 μ m . II
We present angular size measurements of 22 oxygen-rich Mira variable stars. These data are part of a long term observational program using the Infrared Optical Telescope Array (IOTA) to characterize the observable behavior of these stars. Complementing the infrared angular size measurements, values for variable star phase, spectral type, bolometric flux and distance were established for stars i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of occupational hygiene
دوره 58 1 شماره
صفحات -
تاریخ انتشار 2014