Velocity criteria for intracranial stenosis revisited: an international multicenter study of transcranial Doppler and digital subtraction angiography.

نویسندگان

  • Limin Zhao
  • Kristian Barlinn
  • Vijay K Sharma
  • Georgios Tsivgoulis
  • Luis F Cava
  • Spyros N Vasdekis
  • Hock Luen Teoh
  • Nikos Triantafyllou
  • Bernard P L Chan
  • Arvind Sharma
  • Konstantinos Voumvourakis
  • Elefterios Stamboulis
  • Maher Saqqur
  • Mark R Harrigan
  • Karen C Albright
  • Andrei V Alexandrov
چکیده

BACKGROUND AND PURPOSE Intracranial atherosclerotic disease is associated with a high risk of stroke recurrence. We aimed to determine accuracy of transcranial Doppler screening at laboratories that share the same standardized scanning protocol. METHODS Patients with symptoms of cerebral ischemia were prospectively studied. Stroke Outcomes and Neuroimaging of Intracranial Atherosclerosis (SONIA) criteria were used for identification of ≥50% stenosis. We determined velocity cutoffs for ≥70% stenosis on digital subtraction angiography by Warfarin-Aspirin Symptomatic Intracranial Disease criteria and evaluated novel stenotic/prestenotic ratio and low-velocity criteria. RESULTS A total of 102 patients with intracranial atherosclerotic disease (age 57±13 years; 72% men; median National Institutes of Health Stroke Scale 3, interquartile range 6) provided 690 transcranial Doppler/digital subtraction angiography vessel pairs. On digital subtraction angiography, ≥50% stenosis was found in 97 and ≥70% stenosis in 62 arteries. Predictive values for transcranial Doppler SONIA criteria were similar (P>0.9) between middle cerebral artery (sensitivity 78%, specificity 93%, positive predictive value 73%, negative predictive value 94%, and overall accuracy 90%) and vertebral artery/basilar artery (69%, 98%, 88%, 93%, and 92%). As a single velocity criterion, most sensitive mean flow velocity thresholds for ≥70% stenosis were: middle cerebral artery>120 cm/s (71%) and vertebral artery/basilar artery>110 cm/s (55%). Optimal combined criteria for ≥70% stenosis were: middle cerebral artery>120 cm/s, or stenotic/prestenotic ratio≥3, or low velocity (sensitivity 91%, specificity 80%, receiver operating characteristic 0.858), and vertebral artery/basilar artery>110 cm/s or stenotic/prestenotic ratio≥3 (60%, 95%, 0.769, respectively). CONCLUSIONS At laboratories with a standardized scanning protocol, SONIA mean flow velocity criteria remain reliably predictive of ≥50% stenosis. Novel velocity/ratio criteria for ≥70% stenosis increased sensitivity and showed good agreement with invasive angiography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-time validation of transcranial Doppler criteria in assessing recanalization during intra-arterial procedures for acute ischemic stroke: an international, multicenter study.

BACKGROUND AND PURPOSE We sought to evaluate the diagnostic accuracy of ultrasound criteria for recanalization during real-time transcranial Doppler monitoring of intra-arterial reperfusion procedures in acute ischemic stroke patients in an international, multicenter study. METHODS Consecutive acute ischemic stroke patients with proximal intracranial occlusions underwent intra-arterial reperf...

متن کامل

Computed Tomography Angiography in the Stroke Outcomes and Neuroimaging of Intracranial Atherosclerosis (SONIA) Study.

BACKGROUND The Stroke Outcomes and Neuroimaging of Intracranial Atherosclerosis (SONIA) study validated noninvasive imaging tests of intracranial atherosclerosis against catheter angiography in a prospective, blinded, multicenter setting. Critical evaluation of transcranial Doppler (TCD) and magnetic resonance angiography in the SONIA study standardized their performance and interpretation. We ...

متن کامل

Transcranial color-coded duplex sonography for detection of distal internal carotid artery stenosis.

BACKGROUND AND PURPOSE Gradation of high-grade intracranial internal carotid artery (ICA) stenosis poses a challenge to noninvasive neurovascular imaging, which seems critical for angioplasty in the ICA segments C1 and C5. We investigated cutoff values of intracranial ICA stenosis for transcranial color-coded sonography (TCCS) and compared this method with the "gold standard," digital subtracti...

متن کامل

Noninvasive detection of diffuse intracranial disease.

BACKGROUND AND PURPOSE Intracranial arterial stenosis increases flow velocities on the upslope of the Spencer's curve of cerebral hemodynamics. However, the velocity can decrease with long and severely narrowed vessels. We assessed the frequency and accuracy for detection of focal and diffuse intracranial stenoses using novel diagnostic criteria that take into account increased resistance to fl...

متن کامل

Results of Transcranial Doppler in Children with Sickle Cell Disease: Correlation between the Time-Averaged Mean of Maximum Velocity and Some Hematological Characteristics

Abstract Background: Transcranial Doppler ultrasonography results have not been previously studied in among Iranian sickle cell anemia patients. The present study was performed to evaluate the pattern of intracranial flow velocities among Iranian children with sickle cell anemia and the hematological parameters that can affect the time-averaged mean of maximum velocity in major intracranial...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 42 12  شماره 

صفحات  -

تاریخ انتشار 2011