Fuzzy Control Strategy for Seismic Response Reduction of Smart Base Isolated Benchmark Building

نویسندگان

  • Kang-Min Choi
  • Hyung-Jo Jung
  • In-Won Lee
چکیده

Control strategy based on fuzzy algorithm is presented for response reduction of the seismically excited base-isolated building, which is an eight story base isolated non-linear building similar to existing buildings in Los Angeles, California. When a control method based on fuzzy algorithm to a structure is used for vibration reduction, it has inherent robustness, easiness to treat the uncertainties of input data from the ground motion and structural vibration sensors and its ability to handle the non-linear behavior of the structure because of no need of exact mathematical model of the structure. This fuzzy algorithm is applied to both of active and semiactive control systems. The results of the numerical simulations show that the proposed control systems could be beneficial in reducing seismic responses of base isolated structures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Structural control benchmark problem: Phase II—Nonlinear smart base-isolated building subjected to near-fault earthquakes

Many branches of engineering, mathematics, and sciences, have relied on benchmark problems as a standard means to compare different solution techniques. Since 1996, the ASCE Structural Control and Monitoring Committee and Task Group on Benchmark Problems, the U.S. Panel on structural control, and IASCM have developed a series of benchmark control problems that offer a set of carefully modeled r...

متن کامل

Semiactive control strategy for a phase II smart base isolated benchmark building

This paper presents a semiactive control strategy for the seismic protection of the phase II smart base isolated benchmark building subjected to near-fault earthquakes. Magnetorheological (MR) fluid dampers controlled by an optimal direct output feedback control algorithm with a voltage generator are used as semiactive control devices. The benchmark building is an eight-story base isolated buil...

متن کامل

Fuzzy control of piezoelectric friction dampers for seismic protection of smart base isolated buildings

This study proposes two fuzzy logic controllers (FLCs) for operating control force of piezoelectric friction dampers used for seismic protection of base-isolated buildings against various types of earthquake excitations. The first controller employs a hierarchic control strategy in which a higher-level supervisory controller operates a single sub-level FLC by modifying its input normalization f...

متن کامل

Self-Tuning Fuzzy Control for Seismic Protection of Smart Base-Isolated Buildings Subjected to Pulse-Type Near-Fault Earthquakes

Pulse-type near-fault earthquakes have obvious long-duration pulses, so they can cause large deformation in a base-isolated system in contrast to non-pulse-type near-fault and far-field earthquakes. This paper proposes a novel self-tuning fuzzy logic control strategy for seismic protection of a base-isolated system, which can operate the control force of the piezoelectric friction damper agains...

متن کامل

Study and Comparison of Seismic Behaviour of Isolator-Damper Hybrid Control System with Conventional Structural Systems

In this paper, in addition to introduce a hybrid structural system contained local isolators and dampers, its behavior and functional capabilities were studied on a conventional structure. For this purpose, an RC frame building with six-story was designed based on valid codes and then, in four cases based on the number of spans, it was split into two separate adjacent frames. Base isolation was...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004