Simulated flying altitude and performance of continuous positive airway pressure devices.

نویسندگان

  • Maria Sehlin
  • Helge Brändström
  • Ola Winsö
  • Michael Haney
  • Karin Wadell
  • Fredrik Ohberg
چکیده

INTRODUCTION Continuous positive airway pressure (CPAP) is used in air ambulances to treat patients with impaired oxygenation. Differences in mechanical principles between CPAP devices may affect their performance at different ambient air pressures, as will occur in an air ambulance during flight. METHODS Two different CPAP systems, a threshold resistor device and a flow resistor device, at settings of 5 and 10 cm H₂O were examined. Static pressure, static airflow, and pressure during simulated breathing were measured at ground level and at three different altitudes [2400 m (7874 ft), 3000 m (9843 ft), and 10,700 m (35,105 ft)]. RESULTS When altitude increased, the performance of the two CPAP systems differed during both static and simulated breathing pressure measurements. With the threshold resistor CPAP, measured pressure levels were close to the preset CPAP level. Static pressure decreased 0.71 ± 0.35 cm H₂O at CPAP 10 cm H₂O compared to ground level and 35,105 ft (10,700 m). With the flow resistor CPAP, as the altitude increased, CPAP produced pressure levels increased. At 35,105 ft (10,700 m), the increase was 5.13 ± 0.33 cm H₂O at CPAP 10 cm H₂O. DISCUSSION The velocity of airflow through the flow resistor CPAP device is strongly influenced by reduced ambient air pressure, leading to a higher delivered CPAP effect than the preset CPAP level. Threshold resistor CPAP devices seem to have robust performance regardless of altitude. Thus, the threshold resistor CPAP device is probably more appropriate for CPAP treatment in an air ambulance cabin, where ambient pressure will vary during patient transport.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Nasal Continuous Positive Airway Pressure Therapy with and without Prophylactic Surfactant in Preterm Neonates

Background: Preterm labor is at risk for respiratory distress syndrome (RDS) and sometimes requires to mechanical ventilation (MV) and surfactant therapy. Continuous positive airway pressure (CPAP) and Nasal Continuous positive airway pressure (NCPAP) are the methods of respiratory support especially for using in RDS of neonates. In other method surfactant is administered to babies via tracheal...

متن کامل

Technology for noninvasive mechanical ventilation: looking into the black box

Current devices for providing noninvasive respiratory support contain sensors and built-in intelligence for automatically modifying ventilation according to the patient's needs. These devices, including automatic continuous positive airway pressure devices and noninvasive ventilators, are technologically complex and offer a considerable number of different modes of ventilation and setting optio...

متن کامل

Exacerbation of sleep apnoea by frequent central events in patients with the obstructive sleep apnoea syndrome at altitude: a randomised trial.

BACKGROUND Many patients with the obstructive sleep apnoea syndrome (OSA) travel to the mountains for recreational and professional activities while temporarily discontinuing continuous positive airway pressure (CPAP) treatment. A study was undertaken to evaluate the hypothesis that altitude would aggravate their hypoxaemia, sleep-related breathing disturbances and impair daytime performance. M...

متن کامل

Sudden Complete Versus Gradual Weaning from Nasal Continuous Positive Airway Pressure in Preterm Neonates: A Randomized Controlled Trial

Background: Continuous positive airway pressure (CPAP) is used as respiratory support in preterm neonates; however, the best weaning method has not yet been determined. In this study, we compared sudden complete and gradual weaning from nasal CPAP (NCPAP) in preterm newborns. Methods: This randomized controlled trial was conducted on 62 prete...

متن کامل

Pressure stability with CPAP devices: A bench evaluation.

BACKGROUND Continuous positive airway pressure (CPAP) maintains a constant pressure to reduce the patient's work of breathing (WOB). The aim of this study was to measure the additional WOB imposed by four current CPAP devices during simulation of a difficult but commonly encountered clinical situation. METHOD Flow contour, respiratory system compliance and total lung-airway resistance of a pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Aviation, space, and environmental medicine

دوره 85 11  شماره 

صفحات  -

تاریخ انتشار 2014