Determination of Vocs in groundwater at an industrial contamination site using a homemade low-density polyethylene passive diffusion sampler.

نویسندگان

  • Xu Ma
  • Zhiqiang Tan
  • Long Pang
  • Jingfu Liu
چکیده

A home-made inexpensive passive diffusion bag (PDB) sampler, prepared by filling deionized water in low-density polyethylene (LDPE) tubes, was evaluated for volatile organic compounds (VOC) sampling in groundwater at industrial contamination sites. Impacts of environmentally relevant conditions on the sampling equilibration time and partitioning of VOCs between the sampler and the water sample were investigated. Sample salinity, agitation and temperature can influence the equilibration time, but generally sampling equilibration was obtained in 14 days under real field sampling of VOCs in groundwater. Both laboratory study and field testing in a contaminated site showed that the VOC concentrations in the developed sampler were equal to those in the water samples at equilibrium. Coupled with a purge and trap concentrator-gas chromatograph-mass spectrometer (P&T-GC-MS), the developed PDB sampler provided a low-cost sampling device for routine monitoring of VOCs in groundwater in wells, with LODs in the range of 2.9-10 microg/L. The proposed PDB was applied to determine VOCs in groundwater at an industrial contamination site, and the present results agreed well with those determined using conventional pump-and-sample monitoring. All the studied 13 VOCs were tested in the four wells in the industrial contamination sites, with their concentrations in the range of 12-73660 microg/L. In addition, while benzene and toluene were heavily contaminated up to a maximum concentration of 74000 tg/L and 6000 microg/L, respectively, 1,2,3-trichlorobenzene and bromobenzene had relatively low contamination levels (below 25 microg/L).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preliminary Results on the Use of Leather Chrome Shavings for Air Passive Sampling

A new passive sampler based on low-density polyethylene (LDPE) layflat tube filled with chrome shavings from tannery waste residues was evaluated to determine volatile organic compounds (VOCs) in indoor and outdoor areas. VOCs were directly determined by head space-gas chromatography-mass spectrometry (HS-GC-MS) without any pretreatment of the sampler and avoiding the use of solvents. Limit of ...

متن کامل

Evaluating the Relationship between Equilibrium Passive Sampler Uptake and Aquatic Organism Bioaccumulation.

This Critcal Review evaluates passive sampler uptake of hydrophobic organic contaminants (HOCs) in water column and interstitial water exposures as a surrogate for organism bioaccumulation. Fifty-seven studies were found where both passive sampler uptake and organism bioaccumulation were measured and 19 of these investigations provided direct comparisons relating passive sampler uptake and orga...

متن کامل

Grafting of Acrylamide to Low Density Polyethylene During Melt Processing

Acrylamide was grafted in low density polyethylene during melt processing in the presence of a free radical initiator using a torque rheometer in a closed system. Effects of processing time, acrylamide and benzoyl peroxide concentrations were studied. FTIR studies revealed that the degree of grafting increased by an increase in acrylamide concentration. Maximum grafting was obtained at 7 mi...

متن کامل

Passive Sampling of Aromatic Hydrocarbons Toluene, Xylene and Ethylbenzene Using Activated Carbon Fabric in Ambient Air of Tehran

Background & Objectives: Air pollution is one of the most important environmental problems in large cities. Aromatic hydrocarbons as volatile organic compounds (VOCs) have been listed in Hazardous Air Pollutants (HAPs) by Environmental Protection Agencies (EPA). The aim of this study is Passive sampling and determination of aromatic hydrocarbons (AHs) toluene, xylene and ethylbenzene using ...

متن کامل

Estimation of Measurement Uncertainties for the DGT Passive Sampler Used for Determination of Copper in Water

Diffusion-based passive samplers are increasingly used for water quality monitoring. While the overall method robustness and reproducibility for passive samplers in water are widely reported, there has been a lack of a detailed description of uncertainty sources. In this paper an uncertainty budget for the determination of fully labile Cu in water using a DGT passive sampler is presented. Uncer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of environmental sciences

دوره 25 11  شماره 

صفحات  -

تاریخ انتشار 2013